5-4 Alarm Page

Settings (continued)

5-4 Alarm Page

This page is for setting actions when there is an alarm. Up to 10 actions may be set.

This page can be used upon access via AadminB or AoperatorB. Press the AOKB button to enable the new settings upon changing. If the AOKB button is pressed upon entering an invalid value, a warning message will appear and entry will be denied. Press the ACancelB button to restore the invalid entry to the current value.

A B C D

A

Action

For specifying the type of action.

 

 

Disable

: Do not invoke action.

 

 

Mail

: Specify the mail address of the destination. An action number will be added to

 

 

 

the mail subject, as shown in the following example.

 

 

 

Alarm from VN-E4: No. 1

 

 

 

To attach a message to the mail, enter the message in AMail CommentB.

 

 

 

Refer to A5-5 Alarm Environment PageB for mail environment settings.

 

 

FTP

: FTP the JPEG as specified in AInput SourceB. Refer to A5-5 Alarm

 

 

 

Environment PageB for FTP environment settings. FTP can be set on only 1

 

 

 

action out of the 10 actions.

 

 

TCP

: Send message entered in the ATCP/UDP CommentB field to the destinations

 

 

 

specified in AIP AddressB and APort NumberB via ATCPB.

 

 

UDP

: Send message entered in the ATCP/UDP CommentB field to the destinations

 

 

 

specified in AIP AddressB and APort NumberB via AUDPB.

 

 

Pin Output Make : Change alarm output to Make. Refer to A5-5 Alarm Environment PageB on

 

 

 

parameter settings for alarm output.

 

 

Pin Output Break: Change alarm output to Break. Refer to A5-5 Alarm Environment PageB on

 

 

 

parameter settings for alarm output.

 

 

 

B

1st Trigger

For specifying the first trigger to invoke the action. Either alarm input (make), alarm input (break)

 

 

or motion detect can be selected. Refer to A5-5 Alarm Environment PageB on parameter settings

 

 

for alarm input. When the second trigger is turned off, the action will be invoked by only the first

 

 

trigger. In addition, when motion detection is selected as the first trigger, AMax. IntervalB and

 

 

A2nd TriggerB will not be available for selection, and only the first trigger will function.

 

 

 

C

Max. Interval

Valid only when the second trigger is specified. For specifying the maximum interval between the

 

 

first and second triggers. Action will be invoked when second trigger occurs after first trigger

 

 

within the maximum interval.

 

 

 

D

2nd Trigger

For specifying the second trigger to invoke the action. Either alarm input (make) or alarm input

 

 

(break) can be selected. Unlike the first trigger, motion detect is not available as a choice. Refer

 

 

to A5-5 Alarm Environment PageB on parameter settings for alarm input.

 

 

 

 