Technical Data

TV

B/G standard

TT1 = 5.5 MHz, TT2 = 5.74 MHz

 

D/K standard

TT1 = 6.5 MHz, TT2 = 6.26 MHz

 

I standard

TT1 = 6.0 MHz

 

 

M/N standard

TT1 = 4.5 MHz, TT2 = 4.72 MHz

 

M1 standard

TT1 = 4.5 MHz

 

 

L standard

AM 6.5 MHz, Nicam = 5.85 MHz

 

B/G standard

Nicam = 5.85 MHz

 

 

I standard

Nicam = 6.552 MHz

 

FM

FM audio processing 48 MHz...858 MHz

 

 

 

 

 

Sound carrier measurement

TV

Standard B/G

5.5 MHz, 5.74 MHz,

 

 

 

5.85 MHz

 

 

 

D/K standard

6.5 MHz, 6.26 MHz

 

 

 

I standard

6.0 MHz, 6.552 MHz

 

 

 

L standard

6.5 MHz, 5.85 MHz

 

 

 

M/N standard

4.5 MHz, 4.72 MHz

 

 

 

M1 standard

4.5 MHz

 

 

 

 

 

 

Nicam decoder

 

 

 

 

Sound carrier distance

 

TV 5.58 MHz with B/G, D/K, L standards

 

 

 

6.552 MHz with I standard

 

 

 

 

 

 

Nicam BER

TV

0-4 x 10-2

 

 

DVB-S modulation method1)

QPSK

 

 

 

 

DVB-C modulation method1)

64 QAM, 128 QAM, DOCSIS 64 QAM (MER and Offset only)

 

 

DVB-T modulation method1)

OFDM, 2k, 8k, QPSK, 16 QAM, 64 QAM (Option)

DVB-S-MER1)

 

-20 dB

 

 

 

 

 

 

 

DVB-C-MER1)

 

-32 dB

 

 

 

 

 

 

 

DVB-T-MER1)

 

-32 dB

(Option)

 

 

 

 

 

 

DVB-S-BER pre-Viterbi1)

 

0 – 2.8 x 10-2

 

 

 

 

 

 

DVB-C-BER pre-Reed Solomon1)

0 – 2.8 x 10-2

 

 

 

 

 

 

 

DVB-T-BER pre-Viterbi1)

 

0 – 2.8 x 10-2

(Option)

 

DVB-S carrier-offset-measurement1)

 

 

 

 

 

 

 

DVB-C carrier-offset-measurement1)

 

 

 

 

 

 

 

DVB-T carrier-offset-measurement1)

(Option)

 

 

 

 

 

 

LNB supply voltage

SAT

0, 10 V...20 V, max. 500 mA

 

External feeding voltage

TV

0, 5 V...9.9 V, max. 100 mA

 

 

 

 

LNB control

SAT

22 kHz, 60 Hz, DiSEqC™, Simple DiSEqC™

 

 

 

 

 

SCART output

 

1 Vpp/75 Ohm

 

 

1)For measuremts exceeding 100 dBµV please use the enclosed attenuation plug, as otherwise no video representation and no MER and BER measurements are possible.