Commissioning
Setup-Menu
The basic setting (status of the MSK 25 after switching it on) can be set in the Setup menu.
Factory Setting on Delivery
Parameter
Setting
POWER ON | TV |
LNB DC | OFF |
LEVEL | dBµV |
Low Level Mute | ON |
Setup Menu Setting
Setup Menu Call-Up
POWER ON
1=TV 2=SAT 3=FM
1. Setup menu
LNB DC
1=OFF 2=ON
2. Setup menu
Level
1=dBµV 2=dBmV
3. Setup menu
LOW LEVEL MUTE
1=OFF 2=ON
4. Setup menu
|
|
CH: .07. | TV |
LEV:____.__dBµV |
|
|
|
|
|
Basic setting |
|
Press [2ndF] and [SETUP].
The particular mode (TV, SAT, FM) is selected and
[ENTER.]
The following requests appear:
Press either [1] or [2] to switch on/off the LNB voltage supply.
Press [ENTER] to retain the current setting.
Press either [1] or [2] to determine the measurement unit the level is to be displayed with.
Press [ENTER] to retain the current setting.
Set or offset the mute function by pressing either [1] or [2]. Select „ON“ to mute the MSK 25 until the input signal on the RF input exceeds 30 dBµV.
Press [ENTER] to retain the desired setting.
Unless the factory settings have been changed, the indication opposite is displayed.
After setting the Low Level Mute, the 4th Setup menu will be exitted automatically and the basic setting will be displayed.