SAT measurement

SAT Analogue Level Measurement

Once you have entered a frequency, the level is measured automatically and displayed either in dBµV or dBmV (depending on the basic configuration) on the LC display. The input level can be measured in the range of 30 dBµV to 120 dBµV (-30 dBmV to 60 dBmV).

 

 

FR:1508.0MHz

SAT

LEV: 86.5dBuV

A │

 

 

 

 

LC display:

Frequency: 1508 MHz

Mode: SAT

Level measured: 86.5 dBµV A

Level Overflow and Level Underflow

 

 

FR:1508.0MHz

SAT

LEV: __._dBuV

A

 

 

 

 

The LC display indicates underflow at a level of < 30 dBµV. The following indications appear on the display:

frequency: 1508 MHz

mode: SAT

level: underflow

 

 

FR:1508.0MHz

SAT

LEV: ¯¯˙¯dBuV

A │

 

 

 

 

Note

The LC display indicates overflow at a level of > 120 dBµV. The following indications appear on the display:

frequency: 1508 MHz

mode: SAT

level: overflow

DVB-S signal levels can only be measured when the digital reception is set.

SAT DVB-S Level Measurement

LC display when the DVB-S level is measured:

The change-over from the analogue measurement to the digital level measurement is described in chapter ‚standard change-over‘

 

 

FR:1236.0MHz

SAT

LEV: 86.5dBuV

D

 

 

 

 

Frequency 1236 MHz

Mode: SAT DVB-S

Level measured: 86.5 dBµV D