Spectrum Measurement

SAT Spectrum

SAT-Full

TV Spectrum

The frequency spectrum in the SAT, TV and FM modes may be displayed on the TFT screen for evaluation purposes.

You can call up the function ‚spectrum measurement‘ in each particular mode (SAT, TV, FM).

Command for ‚spectrum measurement‘: [2ndF] [Spect].

Back to the regular LC display: 2 x [2ndF].

By pressing [-]and [+], you can move a cursor on the level curve in order to measure certain level minima and level maxima. The frequency and the value measured are displayed in the top row of the screen. The measurement range is displayed in dBµV on the ordinate on the left hand side of the screen. The level measurement range is set automatically.

The level peak value is measured in the spectrum analysis.

In SAT mode (see corresponding chapter), the entire SAT spectrum from 920 MHz...…2150 MHz can be displayed.

LC display

The TV mode (see corresponding chapter) is divided into four ranges which can be selected by pressing either [1], [2], [3] or [4] , see screen as well as explanation shown below.

Example for UHF

44

Page 44
Image 44
Kathrein MSK 25 manual Spectrum Measurement, SAT Spectrum, TV Spectrum, SAT-Full