Kenmore 580.75085 115V-230V, Observe All Local Codes And Ordinances, Recommended Grounding Method

Models: 580.75135 580.75116 580.75085

1 40
Download 40 pages 40.86 Kb
Page 4
Image 4
OBSERVE ALL LOCAL CODES AND ORDINANCES.

OBSERVE ALL LOCAL CODES AND ORDINANCES.

DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUND PRONG.

ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE.

208!230-volt 60 Hz and 115-volt 60 Hz, AC only, 15A fused and properly grounded electrical supply is required. A time delay fuse or time delay circuit breaker is recommended. Use a dedicated circuit, serving only this appliance.

DO NOT USE AN EXTENSION CORD.

115V-230V-

d

RECOMMENDED GROUNDING METHOD

For your personal safety, this appliance must be grounded. This appliance has a power supply cord with a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into e mating grounding type wall receptacle and grounded in accordance with the National Electrical Code (ANSI/NFPA 70) latest edition and all local codes and ordinances. If a mating wall receptacle is not available, it is the personal responsibility and obligation of the customer to have a properly grounded 3-prong wall receptacle installed by a qualified electrician.

Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

NOTE; The shape may be different according to its model

Use Wail Receptacle

Power Supply

Standard125V,

3-wiregrounding

receptacle rated 15A, 125VAC

Standard 250V, 3-wi_g_unding receptacle rated 15A, 25aVAC

Use 15 AMP, time

delay fuse or 15 AMP, circuit breaker,

Electrical Shock Hazard

Plug into a grounded 3 prong outlet. Do not remove ground prong.

Standard

250V,

 

 

3_wire grounding

Use 20 AMP. time

receptacle

rated

delay

fuse or 20 AMP,

20A, 25av

AC

circuit

breaker,

grounding

plug3-pron_

Test

Reset3_-pron_ _G!

receptacle

Powerprong

supply cord

(208/230-volt 60 Hz)

-4-

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

(115-volt 60 Hz)

Page 4
Image 4
Kenmore 580.75085 115V-230V, Observe All Local Codes And Ordinances, Electrical Ground Is Required On This Appliance