staHation nst uctions (oont n0e¢
Convert The Oven Burner Orifice For LP Gas
Oven Burner:
1.Remove oven door, storage drawer, oven bottom and burner baffle.. The burner orifice spud is located behind a metal shield at the center bottom of range.
2. Remove metal shield and use a 1/2" wrench to turn the burner orifice spud clockwise Tighten spud only until it is snug with the base To prevent leakage, do not overtighten spud or loosen spud after it is snug
St®p 4
Adjusting The ABrAdjustment Shutters For LP Gas
For location of and access to air adjustment shutters, see page 8.
Loosen the Phillips head screw and rotate the shutter to the full open position. With baffle in place, flames should
have approximately
extend beyond the edges of the burner baffle For LP
gas, this should occur when the air adjustment shutter is
completely open After 30
seconds of burner operation, check for flames lifting off burner ports. If lifting is observed, gradually reduce air shutter opening untit flames are stabifized.
Broil Burner:
Use a 1/2" wrench to turn the upper burner orifice spud clockwise Tighten spud only until it is snug with the base To prevent leakage, do not overtighten spud or loosen spud after it is snug
12