FIGURE 4 Installing AC Quick Connect

Installation Instructions

Step 3

Mounting Instructions:CAUTION: YOUR SMOKE/CO ALARM IS SEALED AND THE COVER IS NOT REMOVABLE!

1.To help identify the date to replace the unit, a label has been affixed to the side of the alarm. Write the “Replace by” date (7 years from initial power up) in permanent marker on the label. See Alarm Replacement section for additional information.

2.Remove the mounting bracket from the back of the alarm by holding the mounting bracket and twisting the alarm in the direction indicated by the “OFF”arrow on the alarm cover.

3.After selecting the proper location for your Smoke/CO Alarm, as described on Pages 8-10, and wiring the AC QUICK CON- NECT harness as described in the WIRING INSTRUCTIONS, attach the mounting bracket to the electrical box. To ensure aesthetic alignment of the alarm with the hallway, or wall, the “A” line on the mounting bracket must be parallel with the hallway when ceiling mounted, or horizontal when wall mounted.

4.Pull the AC QUICK CONNECTOR

through the center hole in the mounting bracket and secure the bracket, making sure that the mounting screws are positioned in the small ends of the keyholes before tightening the screws.

5. Plug the AC QUICK CONNECTOR into the back of the alarm (see figure 4), making sure that

the locks on the connector snap into place. Then push the excess wire back into the electrical box through the hole in the center of the mounting bracket.

6.Install the alarm on the mounting bracket and rotate the alarm in the direction of the “ON” arrow on the cover until the alarm ratchets into place (this ratcheting function allows

for aesthetic alignment). Note: The alarm will mount to the

bracket in 4 positions (every 90 degrees).

13