PRODUCT DATA SHEETS

Base Grille Water Filtration System Model WF-LC400/LC400

Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine (Class I) Taste and Odor and against ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.

Capacity: 400 Gallons (1514 Liters)

Service Flow Rate: 0.5 GPM (1.89 L/min.) @ 60 psi.

Substance Reduction

U.S. EPA

Average

Maximum

Average

Minimum %

Average %

NSF Test

Aesthetic Effects

MCL

Influent

Effluent

Effluent

Reduction

Reduction

Number

Chlorine Taste/Odor

N/A

2.0 mg/L

N/A

0.04 mg/L

N/A

98%

994707

Particulate

N/A

610,000/mL*

N/A

154/mL

N/A

99%

994711

 

 

 

 

 

 

 

 

Contaminant

U.S. EPA

Average

Maximum

Average

Minimum %

Average %

NSF Test

Reduction

MCL

Influent

Effluent

Effluent

Reduction

Reduction

Number

 

 

 

 

 

 

 

 

Cyst

99.95%**

89,250/mL*

6/mL

2.3/mL

99.993%

99.997%

994710

Turbidity

0.5 NTU

29 NTU

0.12 NTU

0.09 NTU

99.59%

99.69%

994710

 

 

 

 

 

 

 

 

Lead: @ pH 6.5

0.015 mg/L

0.16 mg/L***

0.001mg/L

0.001 mg/L

99.4%

99.4%

994708

Lead: @ pH 8.5

0.015 mg/L

0.16 mg/L***

0.002 mg/L

0.001 mg/L

98.8%

99.4%

994709

 

 

 

 

 

 

 

 

*Test requirement is at least 100,000 particles/ml of AC Fine Test Dust. **Cyst performance is % reduction based on NSF Standard 53. ***Test

requirement is 0.15 mg/L ± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.

Base Grille Water Filtration System Model WF-L500/L500

Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine (Class I) Taste and Odor and against ANSI/NSF Standard 53 for the reduction of Lead.

Capacity: 500 Gallons (1893 Liters)

Service Flow Rate: 0.5 GPM (1.89 L/min.) @ 60 psi.

Substance

 

Average

Maximum

Average

Minimum %

Average %

NSF Test

Reduction

 

Influent

Effluent

Effluent

Reduction

Reduction

Number

 

 

 

 

 

 

 

 

Chlorine, Taste/Odor

 

2.0 mg/L

N/A

0.1 mg/L

N/A

95%

981788

 

 

 

 

 

 

 

 

Contaminant

U.S. EPA

Average

Maximum

Average

Minimum%

Average%

NSF Test

Reduction

MCL

Influent

Effluent

Effluent

Reduction

Reduction

Number

Performance††

 

 

 

 

 

 

 

Lead: @ pH 6.5

0.015 mg/L

0.16 mg/L†

0.007 mg/L

0.005 mg/L

95%

97%

976115

Lead: @ pH 8.5

0.015 mg/L

0.14 mg/L†

0.012 mg/L

0.008 mg/L

91%

94%

976116

■It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.

■Model WF-LC400The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. When 90% of the filter’s rated life is used, the filter indicator light changes from green to yellow. When 100% of the filter’s rated life is used, the filter indicator light changes from yellow to red, and it is recommended that you replace the filter. Use replacement cartridge LC400,

part# 9902. 2000 suggested retail price of $39.95 U.S.A./ $49.95 Canada.

■Model WF-NL500The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. When 90% of the filter’s rated life is used, the filter indicator light changes from green to yellow. When 100% of the filter’s rated life is used, the filter indicator light changes from yellow to red, and it is recommended that you replace the filter. Use replacement cartridge L500, part# 4392857. 2000 Suggested retail price of $29.95 U.S.A./ $39.95 Canada.

■The product is for cold water use only.

■Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

■Refer to the “Assistance or Service” section for the Manufacturer’s name, address and telephone number.

■Refer to the “Warranty” section for the Manufacturer’s limited warranty.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

30 - 120 psi (207 - 827 kPa)

Water Temperature

33° - 100° F (0.6° - 37.8° C)

†Test requirement is 0.15 mg/L ± 10%.

††These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.

®NSF is a registered trademark of NSF International.

PART NO. 2209477

 

© 2000 KitchenAid

9/00

® Registered trademark/TM trademark of KitchenAid, U.S.A., KitchenAid Canada licensee in Canada