PRODUCT DATA SHEETS

Base Grille Water Filtration System Model WF-LC400/LC400

Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine (Class I) Taste and Odor and against ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.

Capacity: 400 Gallons (1514 Liters)

Service Flow Rate: 0.5 GPM (1.89 L/min.) @ 60 psi.

Substance Reduction

U.S. EPA

Average

Maximum

Average

Minimum %

Average %

NSF Test

Aesthetic Effects

MCL

Influent

Effluent

Effluent

Reduction

Reduction

Number

Chlorine Taste/Odor

N/A

2.0 mg/L

N/A

0.04 mg/L

N/A

98%

994707

Particulate

N/A

610,000/mL*

N/A

154/mL

N/A

99%

994711

 

 

 

 

 

 

 

 

Contaminant

U.S. EPA

Average

Maximum

Average

Minimum %

Average %

NSF Test

Reduction

MCL

Influent

Effluent

Effluent

Reduction

Reduction

Number

 

 

 

 

 

 

 

 

Cyst

99.95%**

89,250/mL*

6/mL

2.3/mL

99.993%

99.997%

994710

Turbidity

0.5 NTU

29 NTU

0.12 NTU

0.09 NTU

99.59%

99.69%

994710

 

 

 

 

 

 

 

 

Lead: @ pH 6.5

0.015 mg/L

0.16 mg/L***

0.001mg/L

0.001 mg/L

99.4%

99.4%

994708

Lead: @ pH 8.5

0.015 mg/L

0.16 mg/L***

0.002 mg/L

0.001 mg/L

98.8%

99.4%

994709

 

 

 

 

 

 

 

 

*Test requirement is at least 100,000 particles/ml of AC Fine Test Dust. **Cyst performance is % reduction based on NSF Standard 53. ***Test

requirement is 0.15 mg/L ± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.

Base Grille Water Filtration System Model WF-L500/L500

Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine (Class I) Taste and Odor and against ANSI/NSF Standard 53 for the reduction of Lead.

Capacity: 500 Gallons (1893 Liters)

Service Flow Rate: 0.5 GPM (1.89 L/min.) @ 60 psi.

Substance

 

Average

Maximum

Average

Minimum %

Average %

NSF Test

Reduction

 

Influent

Effluent

Effluent

Reduction

Reduction

Number

 

 

 

 

 

 

 

 

Chlorine, Taste/Odor

 

2.0 mg/L

N/A

0.1 mg/L

N/A

95%

981788

 

 

 

 

 

 

 

 

Contaminant

U.S. EPA

Average

Maximum

Average

Minimum%

Average%

NSF Test

Reduction

MCL

Influent

Effluent

Effluent

Reduction

Reduction

Number

Performance††

 

 

 

 

 

 

 

Lead: @ pH 6.5

0.015 mg/L

0.16 mg/L

0.007 mg/L

0.005 mg/L

95%

97%

976115

Lead: @ pH 8.5

0.015 mg/L

0.14 mg/L

0.012 mg/L

0.008 mg/L

91%

94%

976116

It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.

Model WF-LC400The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. When 90% of the filter’s rated life is used, the filter indicator light changes from green to yellow. When 100% of the filter’s rated life is used, the filter indicator light changes from yellow to red, and it is recommended that you replace the filter. Use replacement cartridge LC400,

part# 9902. 2000 suggested retail price of $39.95 U.S.A./ $49.95 Canada.

Model WF-NL500The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. When 90% of the filter’s rated life is used, the filter indicator light changes from green to yellow. When 100% of the filter’s rated life is used, the filter indicator light changes from yellow to red, and it is recommended that you replace the filter. Use replacement cartridge L500, part# 4392857. 2000 Suggested retail price of $29.95 U.S.A./ $39.95 Canada.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

Refer to the “Assistance or Service” section for the Manufacturer’s name, address and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited warranty.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

30 - 120 psi (207 - 827 kPa)

Water Temperature

33° - 100° F (0.6° - 37.8° C)

Test requirement is 0.15 mg/L ± 10%.

††These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.

®NSF is a registered trademark of NSF International.

PART NO. 2209477

 

© 2000 KitchenAid

9/00

® Registered trademark/TM trademark of KitchenAid, U.S.A., KitchenAid Canada licensee in Canada

Printed in U.S.A.

Page 32
Image 32
KitchenAid 2209477 manual Product Data Sheets