Safety data sheet Océ TDS800 scanner
PRODUCT SAFETY DATA SHEET
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | Number | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | Date | January 2001 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| Model | 
 | 
 | 
 | Océ TDS800 Scanner | 
 | 
 | 
 | |||
| Description | 
 | 
 | 
 | Freestanding scanner, maximum original size 1036 mm x 6000 mm | 
 | |||||
| Max. process speed | 
 | 
 | 
 | 10 m/min | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| Dimensions | Width | 
 | 1320 | mm | 
 | 
 | 
 | |||
| 
 | 
 | Depth | 
 | 640 | mm | 
 | 
 | 
 | ||
| 
 | 
 | Height | 
 | 1235 | mm | 
 | 
 | 
 | ||
| Weight | 
 | 
 | 
 | 147 | kg | 
 | 
 | 
 | ||
| Voltage | 
 | 
 | 
 | 230 | V | 
 | 
 | 
 | ||
| Frequency | 
 | 
 | 
 | 50 | Hz | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 1 | A | 
 | 
 | 
 | |||
| Power consumption,stand by | 
 | 165 | W | 
 | 
 | 
 | ||||
| Power consumption, operation | 
 | 180 | W at continuous operation | 
 | 
 | |||||
| EPA ENERGY STAR ® | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| * Power consumption low power | 
 | 
 | 7 W | 
 | 
 | 
 | ||||
| Mains connection | 
 | 
 | 
 | Cable with plug | 
 | 
 | 
 | |||
| Safety class | 
 | 
 | 
 | I | (IEC 536) Protective earth connection | 
 | 
 | |||
| Protection class | 
 | 
 | 
 | IP 20 | (IEC 529) | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| Sound pressure level | 
 | Stand byIn operation | 
 | 
 | 
 | |||||
| 
 | 43 dB(A)main body 53 dB(A) | 
 | 
 | 
 | ||||||
| (at operator position) | 
 | impulse Li = 9 dB(A) | 
 | 
 | 
 | |||||
| Sound power level | 
 | 
 | 
 | 56 dB(A)main body 68 dB(A) | 
 | 
 | 
 | |||
| Radio interference | 
 | 
 | 
 | Complies with Directive 89/336/EEC and FCC rules and regulations, part 15 Class A. | ||||||
| Radiation | 
 | 
 | 
 | Below the Threshold Limit Values for UV, Visible and IR radiation (TLV list of ACGIH) | ||||||
| Heat emission | 
 | 
 | 
 | Standby165 W; at continuous operation 180 W | 
 | 
 | ||||
| Ozone emission | 
 | 
 | 
 | Not applicable | 
 | 
 | 
 | 
 | 
 | |
| Room volume | 
 | 
 | 
 | No special requirements | 
 | 
 | 
 | |||
| Room ventilation | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| Consumables | 
 | 
 | 
 | Not applicable | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| Additional safety information | 
 | None | 
 | 
 | 
 | 
 | 
 | |||
| 
 | Approved according to | Approved according to | EPA ENERGY STAR ® | 
 | ||||||
| 
 | 
 | 
 | 
 | Low Voltage Directive | EMC Directive | 
 | 
 | |||
| 
 | 
 | 
 | 
 | 
 | 73/23/EEC | 
 | 
 | 89/336/EEC | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
Copyright © 2001 
The content of this safety data sheet is subject to the disclaimer of liability on page 260 of this manual.
| 262 | Océ TDS800 User Manual | 