Safety data sheet Océ TDS800 printer

PRODUCT SAFETY DATA SHEET

 

 

 

 

 

 

 

 

 

 

Number

E-730-a-UK

 

 

 

 

 

 

 

 

 

 

Date

 

January 2001

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

 

Océ TDS800 printer engine

 

 

 

 

 

 

Description

 

 

Electrophotographic printer, console model, plain paper, organic photoconductive drum,

 

 

 

 

powder toner .

 

 

 

 

 

 

 

 

 

Max. process speed

 

 

13 m/min

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

Width

1720 mm

 

 

 

 

 

 

 

 

 

Depth

1146

mm

 

 

 

 

 

 

 

 

 

Height

1400

mm

 

 

 

 

 

 

 

Weight

 

 

939

kg

 

 

 

 

 

 

 

Voltage

 

 

230

V

400

V

415

V

 

 

 

Frequency

 

 

50

Hz

50

Hz

50

Hz

 

 

 

Current-rated

 

 

16/12/11

A

11/6/7

A

11/6/6

A

 

 

 

Power consumption, low power

495

W

 

 

 

 

 

 

 

Power consumption, stand by

820

W

 

 

 

 

 

 

 

Power consumption, operation

4100

W

 

 

 

 

 

 

 

EPA ENERGY STAR ®

 

 

 

 

 

 

 

 

 

 

 

 

* Power consumption sleep mode

13

W (without controller)

 

 

 

 

 

 

Mains connection

 

 

Cables with plug

 

 

 

 

 

 

 

Safety class

 

 

I

(IEC 536) Protective earth connection

 

 

 

 

Protection class

 

 

IP 20

(IEC 529)

 

 

 

 

 

 

 

Sound pressure level

Standby

 

 

In operation

 

 

 

 

46 dB(A)

 

 

main body 59 dB(A)

 

 

 

 

(at bystander position)

 

 

 

impulse Li

= 1 dB(A)

 

 

 

 

Sound power level

 

 

59 dB(A)

 

 

main body 70 dB(A)

 

 

 

 

Radio interference

 

 

Complies with Directive 89/336/EEC and FCC rules and regulations, part 15 Class A.

 

Radiation

 

 

Below the Threshold Limit Values for UV, Visible and IR radiation (TLV list of ACGIH)

 

Heat emission

 

 

Standby 820 W; at continuous operation 4,1 kW

 

 

 

 

 

Ozone emission

 

 

0,02 mg/min at continuous operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Room volume

 

 

Recommendation: min. 75 m3

 

 

 

 

 

 

Room ventilation

 

 

Recommendation: min. 37,5 m3/h (natural ventilation)

 

 

 

 

 

 

 

 

For heat evacuation extra ventilation may be necessary

 

 

 

 

Use simulation at random

Room volume and ventilation as recommended

 

m2

 

 

 

operation

 

 

Daily copy volume (much more than average)

1200

 

 

 

 

 

 

 

Total worktime

 

 

 

 

8

h

 

 

 

 

 

 

 

Ozone concentrations:

 

 

 

mg/m3

(<0,0005

ppm)

 

 

 

 

- Time weighted average

 

 

< 0,001

 

 

 

 

- Peak

 

 

 

 

0,0015

mg/m3

( 0,0008

ppm)

 

 

 

 

Threshold Limit Value/Occupational Exposure Limit

mg/m3

 

(0,1

ppm)

 

 

 

 

(Time Weighted Average) for ozone

 

0,2

 

 

 

 

 

Odour Perception Limit for ozone

 

0,04

mg/m3

 

(0,02

ppm)

Consumables

 

 

Océ 9800 OPC (Océ Safety Data Sheet E-194)

 

 

 

 

 

 

 

 

 

Océ E1 Toner (Océ Safety Data Sheet E-198)

 

 

 

 

 

 

 

 

 

Océ Copying Materials

 

 

 

 

 

 

 

Additional safety information

The ozone filter does not have to be replaced to keep the ozone concentration in the

 

 

 

 

 

workplace below 0,04 mg/m3 (i.e. the life of the filter equals that of the apparatus).

 

 

CE-Compliance

 

Approved according to

Approved according to

EPA ENERGY STAR ®

 

 

 

 

 

 

Low Voltage Directive

EMC Directive

 

 

 

 

 

 

 

 

 

73/23/EEC

 

 

89/336/EEC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Copyright © 2001 Océ-Technologies B.V., Venlo, NL

The content of this safety data sheet is subject to the disclaimer of liability on page 260 of this manual.

261

Page 261
Image 261
IBM user manual Safety data sheet Océ TDS800 printer, Product Safety Data Sheet