Set the folded package length)

1Press the ‘Finishing’ card in the ‘Print’ section.

2Press the function key ‘Folded package’.

3Select ‘Length’.

4Enter a range between 276 - 310 mm or 10.9 - 12.2 inch., in steps of 1 mm or 0.1 inch; default 297 mm or 12 inch

Set the binding strip

1Press the ‘Finishing’ card in the ‘Print’ section.

2Press the function key ‘Binding’.

3Select binding enabled or disabled.

4If you selected enabled enter a range between 15 - 30 mm or 0.6 - 1.2 inch, in steps of 1 mm or 0.1 inch; default 20 mm or 0.8 inch.

Set the reinforcement

1Press the ‘Finishing’ card in the ‘Print’ section.

2Press the function key ‘Binding’.

3Select ‘Reinforce’ enabled or disabled.

Note: Reinforcement is only possible with the Standard folding method

You can overrule the standard folding program with settings from the printer driver or the scanner operator panel.

Find more information about Océ printer drivers in the on-line help. How to make folding settings on the Océ TDS800 Scanner panel is described below.

See ‘Standard folding settings’ on page 179 for complete information about defining default folding settings.

Fold settings from the Océ TDS800 scanner operator panel

1Open the ‘Feeding’ card in the ‘Original’ section and press the ‘Legend location’ function key to select the required legend location (‘Leading’ or ‘Trailing’).

Note: Make certain that your legend is always located on your left-hand side to ensure correct positioning of the legend during folding.

2Press the ‘Drawing method’ function key to select ‘Standard’, ‘Ericsson’ or ‘Afnor’ fold.