C |
Drain hose connection
Connect drain hose to an air gap or waste tee using one of the recommended or alternate methods.
Raccordement du tuyau
d’évacuation
Connecter le tuyau d’évacuation à un
DE
A
F
G
C B
H
J
I
N
L
P
O
K
Q
N
S
M R
Recommended Connection Methods
Air Gap
Install Air Gap Kit (Part No. 300096) (A) according to kit instructions. If a different air gap is used, it should be checked to make sure it allows for the same air flow.
Drain hose (B) to air gap (A) to waste tee (C)
Cut drain end of drain hose as shown (D). Do Not cut ribbed section to shorten drain hose (E).
Secure drain hose to air gap with
Connect the air gap to waste tee using a rubber connector (G)* and spring- or
The waste tee connection MUST be ahead of the drain trap (I) and 20 inches (50.8cm) minimum above the floor (J).
Drain hose (K) to air gap (L) to disposer (M)
Knock out disposer inlet plug (N) from inlet. If inlet plug falls inside disposer, you must remove inlet plug before connecting drain hose. If disposer is already installed in sink, you may need to remove disposer from sink to remove plug.
DO NOT cut end of drain hose.
Secure drain hose to air gap with
Connect the air gap to disposer using a rubber connector (P)* and spring- or
Most disposers have 7/8" connectors, or special connectors are available at plumbing supply stores.
The disposer connection MUST be ahead of the drain trap (R) and 20 inches (50.8cm) minimum above the floor (S).
*All parts are available from your dealer.
Méthodes de raccordement recommandées
Brise-siphon
Installer le
Raccordement du tuyau d’évacuation (B) au brise- siphon (A) et au raccord T (C)
Couper l’extrémité du tuyau d’évacuation (D) selon l’illustration. Ne pas couper l’extrémité nervurée pour raccourcir le tuyau d’évacuation (E).
Fixer le tuyau d’évacuation sur le
(F). Si la taille de la bride à ressort est trop grande pour la petite section du tuyau d’évacuation, utiliser une bride plus petite. On peut trouver ces brides plus petites dans les magasins de fournitures de plomberie.
Raccorder le
La connexion au raccord T DOIT être située en amont du siphon
(I)et à au moins 508 mm (20 po)
Raccordement du tuyau d’évacuation (K) au brise- siphon (L) et à un broyeur à déchets (M)
Arracher l’opercule d’obturation (N) à l’entrée du broyeur à déchets. Si l’opercule d’obturation tombe à l’intérieur du broyeur, on doit le retirer avant de connecter le tuyau d’évacuation. Si le broyeur à déchets est déjà installé sur l’évier, il peut être nécessaire de démonter le broyeur de l’évier pour retirer l’opercule d’obturation.
NE PAS couper l’extrémité du tuyau d’évacuation.
Fixer le tuyau d’évacuation sur le
(O).
Raccorder le
Les broyeurs à déchets sont généralement dotés de raccords de 7/8 po; on peut également trouver des raccords spéciaux dans les magasins de fournitures de plomberie.
La connexion au raccord T DOIT être située en amont du siphon
(R)et à au moins 508 mm (20 po)
*Toutes les pièces sont disponibles du marchand.
CD
A
B
E
G
F
J
H
K
M
I
L
Alternate Connection Methods
No Air Gap
If local codes permit, the dishwasher drain hose may be connected directly to a waste tee or waste disposer.
Drain hose (A) to waste tee (B)
Cut drain end of drain hose as shown (C). Do Not cut ribbed section to shorten drain hose (D).
Secure drain hose to waste tee with spring- or
The waste tee connection MUST be ahead of the drain trap (F) and 20 inches (50.8cm) minimum above the floor (G).
Drain hose (H) to disposer (I)
Knock out disposer inlet plug from inlet (J). If inlet plug falls inside disposer, you must remove inlet plug before connecting drain hose. If disposer is already installed in sink, you may need to remove disposer from sink to remove plug.
DO NOT cut end of drain hose.
Secure drain hose to disposer with spring- or
Most disposers have 7/8" connectors, or special connectors are available at plumbing supply stores.
The disposer connection MUST be ahead of the drain trap (L) and 20 inches (50.8cm) minimum above the floor (M).
Autres méthodes de raccordement
Sans brise-siphon
Si le code local le permet, on peut raccorder directement le tuyau d’évacuation du
Raccordement du tuyau d’évacuation (A) au raccord T (B)
Couper l’extrémité du tuyau d’évacuation (C) selon l’illustration. Ne pas couper l’extrémité nervurée pour raccourcir le tuyau d’évacuation
(D).
Fixer le tuyau d’évacuation au raccord T avec une bride à ressort ou à vis (E). Si la taille de la bride à ressort est trop grande pour la petite section du tuyau d’évacuation, utiliser une bride plus petite. On peut trouver ces brides plus petites dans les magasins de fournitures de plomberie.
La connexion au raccord T DOIT être située en amont du siphon (F) et à au moins 508 mm (20 po)
(G).
Raccordement du tuyau d’évacuation (H) à un broyeur à déchets (I)
Arracher l’opercule d’obturation (J) à l’entrée du broyeur à déchets. Si l’opercule d’obturation tombe à l’intérieur du broyeur, on doit le retirer avant de connecter le tuyau d’évacuation. Si le broyeur à déchets est déjà installé sur l’évier, il peut être nécessaire de démonter le broyeur de l’évier pour retirer l’opercule d’obturation.
NE PAS couper l’extrémité du tuyau d’évacuation.
Raccorder le tuyau d’évacuation au broyeur à déchets au moyen de brides à ressort ou à vis (K).
Les broyeurs à déchets sont généralement dotés de raccords de 7/8 po; on peut également trouver des raccords spéciaux dans les magasins de fournitures de plomberie.
La connexion au raccord T DOIT être située en amont du siphon (L) et à au moins 508 mm (20 po)