A-61070 September 1999 2-7
Adjusting the feed
shelf position (semi-
automatic feeder only)
For manual feeding, the feed shelf can be adjusted in the 0°, 30° or 40°
position. For automatic feeding, raise the feed shelf to the 30° or 40°
position.
40° position 30° position
Adjusting the side
guides Before you begin feeding documents into the scanner, adjust the
position of the side guides and feed shelf position.
Adjust the width of the feed shelf side guides to hold the widest
document you will be scanning. Leave approximately 1/16-inch
(2 mm) clearance on each side of the largest document to allow for
proper feeding.
NOTE: Ensure that the documents are center-fed so each
document covers the 2 ½-inch required width as indicated
by the label on the feed tray.