A-61070 September 1999 8-19
option The Read Rate test option establishes the percentage of bar codes read
properly. This option is designed to provide a baseline value as well as
the current read rate. A comparison of the two values provides a measure
of machine performance over time.
When using the Read Rate test option, you can use Kodak Bar Code
Standard Test Documents or customer application documents.
To use the Read Rate test option:
1. Select 3: Rr .
BC Type =
1: EV 2: DP 3: Rr
2. Feed at least 100 test docum ents. As documents are fed into the
transport, the
Doc Count
value will increment.
BC Type =
Rate = % (@100)
When finished, the percentage (%) indicates the read rate of the
documents just processed.
NOTE: To stop the test and leave the percentages unchanged,
press Stop before the 100 documents have been
processed.
• If using the Kodak Bar Code Standard Test document — if
the read rate is significantly lower than in the past, this could be
caused by a deficiency in the equipment. Perform required
maintenance and rerun the test. If the results of the second test
are similar to the first, contact Service.
• If using customer application documents — if the read rate is
significantly lower than in the past, this could be caused by a
deficiency in the bar code quality. Perform the Evaluate option to
determine the cause of the test results.
3. W hen the test is finished, press C to return to normal operation, or
press Stop to remain in the test environment.