4
5
6
3
2
1
7
8
13
9
15
Waterline
16 | 12 |
|
10
14
11
1.Slight lift improves silencing and prevents water backwash into the silencer (keep below the level of the exhaust manifold outlet)
2.Silencer
3.Exhaust manifold outlet
4.Exhaust mixer elbow
5.Heat exchanger (locations vary by model)
6.Coolant recovery tank (located on the unit on some models)
7.Locate the coolant recovery tank at the same height as the heat exchanger
8.Maximum seawater pump lift of 1 m (3 ft.)
9.Seawater strainer
10.Seacock
11.Intake strainer
12.
Figure 4-4 Typical Above-Waterline Installation
13.Minimum exhaust hose pitch of 1.3 cm per 30.5 cm (0.5 in. per ft.)
14.Maximum distance between silencer and exhaust mixer elbow of 3 m (10 ft.)
15.Minimum exhaust hose pitch of 1.3 cm per 30.5 cm (0.5 in. per ft.)
16.Minimum exhaust outlet distance above waterline of 10 cm (4 in.). Note: Vessel fully loaded.
Note: Data applies to both rear- and
Note: Use two hose clamps on each end of all flexible exhaust hose connections.
Note: Read the text for complete explanation of dimensions and other installation considerations.
Section 4 Exhaust System 13 |