Kohler 4EFOZ/5EOZ, 8.5EFOZ, 9EFOZ/10EOZ, 80EFOZ/99EOZ Typical Mid and Below Waterline Installation

Models: 70EFOZ/80EOZ 19EFOZ/23EOZ 100EFOZ/125EOZ 11EFOZ/13EOZ 125EFOZ/150EOZ 13EFOZ/15.5EOZ 11.5EFOZ/14EOZ 17.5EFOZ/20EOZ 23EFOZ/28EOZ 16EFOZ/20EOZ 20EFOZ/24EOZ 33EFOZ/40EOZ 27EFOZ/32EOZ 55EFOZ/65EOZ 3.5EFOZ/4EOZ 40EFOZ/50EOZ 4EFOZ/5EOZ 6.5EFOZ/8EOZ 80EFOZ/99EOZ 9EFOZ/10EOZ 8.5EFOZ

1 92
Download 92 pages 2.29 Kb
Page 25
Image 25

 

2

 

 

 

 

 

3

 

7

8

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

10

1

 

 

 

 

 

21

 

6

 

 

 

 

 

 

 

 

 

 

5

 

 

 

Waterline

19

4

 

 

11

 

 

 

 

20

 

 

16

 

 

 

 

 

 

12

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

13

 

 

17

 

14

TP-5856-4

1.Mounting base

2.Retaining cap

3.Reed valve assembly

4.Maximum silencer vertical lift of 1.2 m (4 ft.)

5.Exhaust mixer elbow distance above waterline; if less than 23 cm (9 in.), a siphon break is required

6.Minimum siphon break distance above waterline of 30.5 cm (1 ft.)

7.Siphon break

8.Exhaust mixer elbow

9.Heat exchanger (locations vary by model)

10.Coolant recovery tank (located on the unit on some models)

11.Indicates the coolant recovery tank is at the same height as the heat exchanger

12.Seawater strainer

13.Seacock

14.Intake strainer

15.Engine-driven seawater pump

16.Minimum exhaust hose pitch of 1.3 cm per 30.5 cm (0.5 in. per ft.)

17.Maximum distance between silencer and exhaust mixer elbow of 3 m (10 ft.)

18.Silencer (customer-supplied)

19.Minimum exhaust hose pitch of 1.3 cm per 30.5 cm (0.5 in. per ft.)

20.Minimum exhaust outlet distance above waterline of 10 cm (4 in.)

21.Exhaust hose (see Figure 4-7 for hose sizes)

Note: Read the text for complete explanation of dimensions and other installation considerations.

Note: Use two hose clamps on each end of all flexible exhaust hose connections.

Note: Data applies to both rear- and side-exhaust installations.

Figure 4-6 Typical Mid and Below Waterline Installation

 

 

Exhaust Hose

 

 

Diameter

Models without Sound Shield

Models with Sound Shield

mm (in.)

 

 

 

 

3.5/4/6.5/8.5/9EFOZ

4/6.5/8.5/9/11/11.5/13/16/17.5/19/20EFOZ

 

 

4/5/8/10EOZ

5/8/10/13/14/15.5/20/23/24EOZ

51

(2.0)

 

 

 

 

11/11.5/13/16/17.5/19/20/23/27EFOZ

27EFOZ

 

 

13/14/15.5/20/23/24/28/32EOZ

32EOZ

76

(3.0)

 

 

 

 

33EFOZ

33EFOZ

 

 

40EOZ

40EOZ

89

(3.5)

 

 

 

 

40/55/70/80/100/125EFOZ

40/55/70/80/100/125EFOZ

 

 

50/65/80/99/125/150EOZ

50/65/80/99/125/150EOZ

102

(4.0)

 

 

 

 

Figure 4-7 Exhaust Hose Sizes

TP-6069 6/03

Section 4 Exhaust System 15

Page 25
Image 25
Kohler 4EFOZ/5EOZ, 8.5EFOZ, 9EFOZ/10EOZ, 80EFOZ/99EOZ, 6.5EFOZ/8EOZ, 40EFOZ/50EOZ Typical Mid and Below Waterline Installation