Max.

Number

 

Amps

Voltage

of Poles

Model(s)

 

 

 

 

20

250

1

4EFOZ

 

 

 

600

3

8.5/11.5EFOZ, 14EOZ

 

 

 

 

 

22

250

2

4EFOZ, 5EOZ

 

 

 

 

25

250

2

5EOZ

 

 

 

 

 

250

1

6.5EFOZ

 

 

 

30

2

6.5EFOZ

 

 

 

 

 

600

3

11.5/17.5/20EFOZ,

 

14/20/24EOZ—3 phase

 

 

 

 

 

 

 

33

250

2

8EOZ

 

 

 

 

35

250

1

4EFOZ

 

 

2

8EOZ

 

 

 

 

 

 

 

250

1

5EOZ

40

 

 

 

600

3

11.5EFOZ,

 

14/20/24EOZ—3 phase

 

 

 

 

 

 

 

42

250

1

9EFOZ

 

 

2

9EFOZ, 8/10EOZ

 

 

 

 

 

 

 

240

1

11/13EFOZ

 

 

 

 

2

11/11.5/17.5EFOZ

 

 

50

 

 

 

250

2

9EFOZ, 10EOZ

 

 

 

 

 

480

3

20/23/27EFOZ,

 

20/28/32EOZ—3 phase

 

 

 

 

 

 

 

55

250

1

5EOZ

 

 

 

 

 

240

1

13EFOZ

 

 

 

 

2

11/13EFOZ, 13/14EOZ

 

 

60

 

 

 

250

1

6.5EFOZ

 

 

 

 

 

600

3

17.5/20EFOZ,

 

20/24/28/32EOZ—3 phase

 

 

 

 

 

 

 

 

240

1

16EFOZ

 

 

 

70

2

13/20EFOZ, 15.5EOZ

 

 

 

 

250

1

6.5EFOZ, 8EOZ

 

 

 

 

 

 

600

3

20/24EOZ—3 phase

 

 

 

 

 

 

1

16/19EFOZ

 

240

 

 

 

2

16EFOZ, 20EOZ—1 phase,

80

 

20/24EOZ—3 phase

 

 

 

 

 

 

250

1

8EOZ

 

 

 

 

 

480

3

23EFOZ—3 phase

 

 

 

 

85

250

1

9EFOZ, 10EOZ

 

 

 

 

 

 

1

19EFOZ

 

240

 

 

90

2

19EFOZ—1 phase

 

20/23EOZ

 

 

 

 

 

 

 

 

480

3

27EFOZ—3 phase

 

 

 

 

 

240

2

23EOZ

100

 

 

 

480

3

23/27EFOZ,

 

28/32EOZ—3 phase

 

 

 

 

 

 

 

 

 

2

23/27EFOZ, 28EOZ—

 

 

1 phase, 27EFOZ—3 phase

125

600

 

 

 

3

23/27EFOZ,

 

 

 

 

28/32EOZ—3 phase

 

 

 

 

 

 

 

150

600

2

28/32EOZ—1 phase,

32EOZ— 3 phase

 

 

 

 

 

 

 

175

600

2

32EOZ—1 phase

 

 

 

 

Figure 6-2 AC Circuit Breaker Ratings (4--27EFOZ and 5--32EOZ Models), Listed By Amps

 

Max.

Number

 

 

Amps

Voltage

of Poles

Type

Model(s)

 

 

 

 

 

60

600

3

UL/IEC

33EFOZ, 40EOZ

 

 

 

 

 

70

600

3

UL/IEC

40EFOZ, 40EOZ

 

 

 

 

 

80

480

3

UL/IEC

40EFOZ, 50EOZ

 

 

 

 

 

100

480

3

UL/IEC

55EFOZ, 50/65EOZ

 

 

 

 

 

100--125

600

3

IEC

33/55EFOZ,

40/65EOZ

 

 

 

 

 

 

 

 

 

100--125

600

3

IEC

70EFOZ, 80EOZ

 

 

 

 

 

125

600

3

UL

33/55EFOZ,

40/65EOZ

 

 

 

 

 

 

 

 

 

125

600

3

UL

70EFOZ, 80EOZ

 

 

 

 

 

128--160

600

3

IEC

33/40EFOZ,

40/50EOZ

 

 

 

 

 

 

 

 

 

128--160

600

3

IEC

70/80EFOZ,

80/99EOZ

 

 

 

 

 

 

 

 

 

150

600

3

UL

33/40EFOZ,

40/50EOZ

 

 

 

 

 

 

 

 

 

150

600

3

UL

70/80EFOZ,

80/99EOZ

 

 

 

 

 

 

 

 

 

160--400

600

3

UL

70/80/100EFOZ,

80/99/125/150EOZ

 

 

 

 

 

 

 

 

 

160--400

600

3

IEC

70/80/100/125EFOZ,

80/99/125/150EOZ

 

 

 

 

 

 

 

 

 

200

600

3

UL

40/55EFOZ,

50/65EOZ

 

 

 

 

 

 

 

 

 

200

600

3

UL

100EFOZ,

99/125EOZ

 

 

 

 

 

 

 

 

 

200--250

600

3

IEC

40/55EFOZ,

50/65EOZ

 

 

 

 

 

 

 

 

 

200--250

600

3

IEC

70/100/125EFOZ,

80/125/150EOZ

 

 

 

 

 

 

 

 

 

240--600

600

3

UL

125EFOZ,

125/150EOZ

 

 

 

 

 

 

 

 

 

250

600

3

UL

55EFOZ, 65EOZ

 

 

 

 

 

250

600

3

UL

70/125EFOZ,

80/125/150EOZ

 

 

 

 

 

 

 

 

 

250--630

600

3

IEC

125EFOZ,

125/150EOZ

 

 

 

 

 

 

 

 

 

Figure 6-3 AC Circuit Breaker Ratings (33--150 kW

 

Models), Listed By Amps

WARNING

Accidental starting.

Can cause severe injury or death.

Disconnect the battery cables before working on the generator set. Remove the negative (--) lead first when disconnecting the battery. Reconnect the negative (--) lead last when reconnecting the battery.

20 Section 6 Electrical System

TP-6069 6/03

Page 30