set description

Syntax:

set description <range> <description> Description:

To set up the human readable description of all ports. Argument:

range syntax: 1,5-7, available from 1 to 26

description: set its port description, max 47 characters

Possible value:

<range>: 1 to 26

Example:

FEL2SW-26(port)# set description 1-26 testport

---------------------------

set flow-control

Syntax:

set flow-control <range> <symmetricasymmetric> Description:

To set up the flow control function of all ports. Argument:

<range>:port range, syntax 1,5-7, available from 1 to 26 <symmetric>: set its flow control as symmetric <asymmetric>: set its flow control as asymmetric

Possible value: <range>: 1 to 26 <symmetricasymmetric>:symmetric or asymmetric

Example:

FEL2SW-26 (port)# set flow-control 3-6 symmetric

---------------------------

set speed-duplex

Syntax:

set speed-duplex <range> <auto>[<101001000> <halffull>] Description:

To set up the speed and duplex of all ports. Argument:

<range>:port range, syntax 1,5-7, available from 1 to 26 <port-speed>:

auto : set auto-negotiation mode

10: set speed to 10M

100: set speed to 100M 1000 : set speed to 1000M <port-duplex> :

half : set to half duplex

full : set to full duplex

Possible value: <range>: 1 to 26

<port-speed> : auto, 10, 100, 1000

<port-duplex> : full, half

Example:

FEL2SW-26 (port)# set speed-duplex 8 100 full