enable symmetric

Syntax:

enable symmetric

Description:

To drop frames from the non-member port.

Argument:

None.

Possible value:

None.

Example:

FEL2SW-26 (vlan)# enable symmetric

---------------------------

set mgt-vlan

Syntax:

set mgt-vlan <state> [vid]

Description:

To assign a management vlan to prevent DoS attack.

Argument:

state: enable or disable this feature

vid : management vlan id

Possible value:

state: 0 for disable; 1 for enable

vid : 1 to 4094

Example:

FEL2SW-26(vlan)# set mgt-vlan 1 1

---------------------------

set mode

Syntax:

set mode <porttag>

Description:

To switch vlan mode between port-based and tag-based modes.

Argument:

<porttag>: port or tag

tag: set tag-based vlan

port: set port-based vlan

Possible value:

<porttag>: port or tag

Example:

FEL2SW-26 (vlan)# set mode tag

---------------------------

set port-group

Syntax:

set port-group <name> <range>

Description:

To add or edit a port-based vlan group.

Argument: