Lennox Hearth MPD-33 Series Vertical Vent Figures/Tables, Rear Vent - THREE ELBOWS, continued

Models: MPD-35 Series MPD-45 Series MPD-33 Series MPD-40 Series

1 32
Download 32 pages 35.84 Kb
Page 15
Image 15
(continued)

VERTICAL VENT FIGURES/TABLES

(continued)

 

 

TABLE C

 

 

H1

H+H1 Maximum

H Maximum

V Minimum

 

feet

(meters)

feet

(meters)

feet

(meters)

 

5

(1.524)

2

(0.610)

1

(0.305)

*Ceiling

 

(3.048)

 

(1.219)

 

(0.610)

Firestop/Spacer

10

4

2

(SV4.5VF)

15

(4.572)

6

(1.829)

3

(0.914)

 

20

(6.096)

8

(2.438)

4

(1.219)

**Wall

 

 

 

 

 

 

 

V + V1

+ H + H1 = 40 feet (12.2 m) Max

 

Firestop/Spacer

 

 

(SV4.5HF)

 

H = 8 feet (2.438 meters) Max.

 

 

 

V1

 

H + H1 = 20 feet (6.096 meters) Max.

 

 

Example: If 20 feet of (H) horizontal vent run is needed, then 4 feet minimum of (V) vertical vent will be required.

This table shows a 1 (V) to 5 (H) ratio. For every 1 foot of (V)

vertical, you are allowed 5 feet of (H) horizontal run, up to aV maximum horizontal run of 20 feet.

Figure 29 - Rear Vent - THREE ELBOWS

*When using Secure Flex, use Firestop/Spacer SF4.5VF

**When using Secure Flex, use Firestop/Spacer SF4.5HF

*Ceiling

Firestop/Spacer

(SV4.5VF)

H

TABLE D

H + H1 Maximum

 

V Minimum

feet

(meters)

feet

(meters)

5

(1.524)

 

Elbow Only

5

(1.524)

1

(0.305)

10

(3.048)

2

(0.610)

15

(4.572)

3

(0.914)

20

(6.096)

4

(1.219)

H + H1 = 20 feet (6.096 m) Max.

V + V1 + H + H1 = 40 ft. (12.192 m) Max.

Example: If 20 feet of (H) horizontal vent run is needed, then 4 feet minimum of (V) vertical vent will be required.

This table shows a 1 (V) to 5 (H) ratio. For every 1 foot of (V) vertical, you are allowed 5 feet of (H) horizontal run, up to a maximum horizontal run of 20 feet.

An elbow is acceptable as 1 foot of vertical rise except where an elbow is the only vertical component in the system. See Figure 35.

Figure 30 - Top Vent - THREE ELBOWS

 

 

*Ceiling

 

V

1

Firestop/Spacer

**Wall

(SV4.5VF)

 

Firestop/Spacer

 

 

 

(SV4.5HF)

 

 

H

 

 

 

H1

V

 

 

 

 

 

*When using Secure Flex,

 

 

 

use Firestop/Spacer

 

 

 

SF4.5VF

 

 

 

**When using Secure

 

 

 

Flex, use Firestop/Spacer

 

 

 

SF4.5HF

 

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

15

Page 15
Image 15
Lennox Hearth MPD-33 Series Vertical Vent Figures/Tables, Rear Vent - THREE ELBOWS, Top Vent - THREE ELBOWS, continued