FIREPLACE SPECIFICATIONS
FRAMING | G | |
SPACERS | ||
| ||
(Top and Sides | H | |
and Rear) | ||
|
(Louvered Front Model Shown)
* *See Note 1
*CONCENTRIC FLUE FLUE -
COMBUSTION AIR -
* MPD models have a top and rear vent MPDR models have only a rear vent MPDT models have only a top vent
J | * *Note 1 - Collars protrude one inch on |
|
Top View
E
A
C
D
| NOTE - Eyebrow |
| hood shown as positioned |
3 (76) | in louvered front model. |
GAS INLET
(Either Side 6 (152) and bottom)
OPTIONAL ELECTRICAL
BINLET KNOCKOUT, REQUIRING A FIELD
PROVIDED JUNCTION BOX |
| |||||
(Either Side) |
| |||||
| K |
|
|
|
| |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N
L
1/2 (13)
* * See Note 1
| ELECTRICAL | |
F** INLET | ||
(42) | ||
COVER PLATE with | ||
M | ||
KNOCKOUT) | ||
|
|
| Front View |
|
|
|
|
| Right Side View |
| **Rear vent models only | ||||
Model No. |
| A | B | C | D | E | **F | G | H | J | K | L | M | N |
in. | 33 1/8 | 30 1/8 | 17 | 27 1/2 | 33 1/8 | 19 5/8 | 21 1/2 | 10 3/4 | 6 13/16 | 3 | 8 11/32 | 2 2/3 | 13 | |
mm | 841 | 765 | 432 | 699 | 841 | 498 | 546 | 273 | 173 | 76 | 212 | 70 | 330 | |
in. | 35 1/8 | 32 1/8 | 19 | 29 1/2 | 35 1/8 | 21 11/16 | 24 7/8 | 12 7/16 | 9 | 3 | 9 | 3 | 16 | |
| mm | 892 | 816 | 483 | 749 | 892 | 551 | 632 | 316 | 220 | 76 | 220 | 76 | 406 |
in. | 40 1/8 | 37 1/8 | 24 | 34 1/2 | 40 1/8 | 26 11/16 | 29 7/8 | 14 15/16 | 9 | 3 | 9 | 3 | 16 | |
| mm | 1019 | 943 | 610 | 876 | 1019 | 678 | 759 | 379 | 220 | 76 | 220 | 76 | 406 |
in. | 40 1/8 | 37 1/8 | 24 | 39 1/2 | 45 1/8 | 26 11/16 | 34 7/8 | 17 7/16 | 9 | 3 | 9 | 3 | 16 | |
| mm | 1146 | 943 | 610 | 1003 | 1146 | 678 | 886 | 443 | 220 | 76 | 220 | 76 | 406 |
Figure 11
Step 3. INSTALL THE VENT SYSTEM General Information
These instructions should be used as a guide- line and do not supersede local codes in any way. Install vent according to local codes, these instructions, the current National Fuel Gas Code
These fireplaces are designed, tested and listed for operation and installation with, and only with, Secure Vent™ Direct Vent System Components, Secure Flex™ Flex- ible Vent Components manufactured by Security Chimneys International and Z- FLEX™ Model GA Venting Systems listed to UL1777 and ULCS635 manufactured by Flexmaster Canada Limited.
These approved vent system components are labeled for identification. DO NOT use anyothermanufacturer'sventcomponents with these appliances. These fireplaces must be vented directly to the outside.
Massachusetts And New York City, NY Requirements
These appliances are approved for installation in the following USA locations listed in the following:
Massachusetts:
These fireplaces are approved for installation in the US state of Massachusetts if the follow- ing additional requirements are met-
•Installation and repair must be done by a plumber or gas fitter licensed in the Common- wealth of Massachusetts.
•The flexible gas line connector used shall not exceed 36 inches (92 centimeters) in length.
•The individual manual
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
9