•“Intermittent problems” on page 50
•“Undetermined problems” on page 51
The
Note: Do the FRU replacement or other actions in the sequence shown in the column headed “FRU or action, in sequence.” If replacing a FRU does not solve the problem, put the original part back in the computer. Do not replace a nondefective FRU.
This index can also help you determine, during regular servicing, what FRUs are likely to need to be replaced next.
A numeric error is displayed for each error detected in POST or system operation. In the displays, n can be any number.
If no numeric code is displayed, check the narrative descriptions of symptoms. If the symptom is not described there, go to “Intermittent problems” on page 50.
Note: For a device not supported by diagnostic codes in the ThinkPad Notebooks, see the manual for that device.
Numeric error codes
Table 2. Numeric error codes
Symptom or error | FRU or action, in sequence | |
|
| |
0175 | System board. | |
Bad CRC1, stop POST |
|
|
not correct. |
|
|
|
|
|
0176 | 1. | Run BIOS Setup Utility, and save the current |
System |
| setting by pressing F10. |
| 2. | System board. |
|
| |
0177 | System board. | |
Bad SVP data, stop POST |
|
|
supervisor password in the EEPROM is not correct. |
|
|
|
|
|
0182 | 1. | Run BIOS Setup Utility. Press F9, and Enter to |
Bad CRC2. Enter BIOS Setup and load Setup |
| load the default setting. Then save the current |
| setting by pressing F10. | |
EEPROM is not correct. | 2. | System board. |
|
|
|
0185 | 1. | Run BIOS Setup Utility. Press F9, and Enter to |
Bad startup sequence settings. Enter BIOS Setup and |
| load the default setting. Then save the current |
load Setup defaults. |
| setting by pressing F10. |
|
| |
0187 | System board. | |
EAIA data access |
|
|
|
| |
0188 | System board. | |
Invalid RFID Serialization Information Area. |
|
|
|
| |
0189 | System board. | |
Invalid RFID configuration information |
|
|
EEPROM checksum is not correct. |
|
|
|
|
|
0190 | 1. | Charge the battery pack. |
Critical | 2. | Battery pack. |
|
|
|