The SETUP Menu

JBL

MAIN MENU

MODE ADJUST AUDIO CONTROLS SETUP

SETUP

INPUTS

SPEAKERS

REAR PANEL CONFIG DISPLAYS VOLUME CONTROLS TRIGGERS

LOCK OPTIONS

SPEAKER SETUP

CUSTOM SETUP SYNTHESIS 7CH SETUP SPEAKER DISTANCES LEVELS CALIBRATION

 

 

R

SR

RR

 

 

80Hz

80Hz

80Hz

 

 

C

 

 

 

 

80Hz

 

 

 

M

L

SL

RL

 

SUB

 

 

 

 

80Hz

 

80Hz

80Hz

80Hz

CUSTOM SETUP

FRONT L/R

80Hz

CENTER

80Hz

SIDE L/R

80Hz

REAR L/R

80Hz

 

 

 

SUB L/R

MONO

 

 

 

SUB XOVER

80Hz

LFE

OFF

SUBWOOFERS L/R

MONO

 

 

 

STEREO

 

 

 

NONE

 

SUB XOVER

 

 

 

 

 

 

FULL

 

 

 

 

30Hz

 

 

40Hz

 

 

50Hz

 

 

60Hz

 

 

70Hz

 

 

80Hz

 

 

THX 80Hz

 

 

90Hz

 

 

100Hz

 

 

110Hz

 

 

120Hz

 

 

 

 

CUSTOM SETUP (continued)

SETUP SPEAKERS CUSTOM SETUP

SUB L/R

(MONO, STEREO, NONE)

The SUB L/R parameter determines the configuration of the MAIN AUDIO OUTPUTS labelled SUBWOOFER L/R. When set to MONO, the front left and right, center, side left and right, and rear left and right channels are combined and sent to the SUBWOOFER L/R outputs. This setting is recommended for all Synthesis systems, regardless of the number of subwoofers being used.

When set to STEREO, low frequencies from the front left, center, side left, and rear left channels are combined and sent to the SUBWOOFER L output. Low frequencies from the front right, center, side right, and rear right are combined and set to the SUBWOOFER R output.

When set to NONE, low frequencies from the FRONT L/R, CENTER, SIDE L/R, and REAR L/R outputs will not be passed to the SUBWOOFER L/R ouputs and will be filtered at the lowest crossover setting selected.

SUB XOVER

(FULL, 30Hz to 120Hz, THX 80Hz)

The SUB XOVER parameter sets the crossover setting for the MAIN AUDIO OUTPUTS labelled SUB L/R. When set to FULL, the unit sends a full-range audio signal to the SUB L/R outputs. When set to a numerical crossover setting, the unit activates a crossover at the selected frequency. Choose the setting that matches the lowest crossover setting in the system. See pages 3-18 and 3-19 for more information about crossover settings.

3-22