CONTROLLING THE MULTIPLE PRODUCT 67

27. On Timer Input (Command: f u)

28. Sleep Time (Command: f f)

 

To select an external input for the current On Time

To set the Sleep Time.

setting and add a new schedule or change the

 

 

 

 

 

 

 

 

 

 

Transmission

 

 

 

 

 

 

 

existing schedule.

 

 

 

 

 

 

 

 

[f][f][ ][Set ID][ ][Data][Cr]

 

 

 

 

 

 

 

 

 

 

Transmission

 

 

 

 

 

 

 

Data 00: Off (Sleep Timer

 

off)

 

 

 

 

 

 

 

 

 

 

 

[f][u][ ][Set ID][ ][Data1][Cr]

 

 

 

 

 

 

 

 

 

 

01: 10 min.

 

 

 

 

 

 

 

 

 

 

[f][u][ ][Set ID][ ][Data1][Data2][Cr]

 

 

 

02: 20 min.

Data (Add schedule)

 

03: 30 min.

20: Input (AV)

 

04: 60 min.

40: Component

 

05: 90 min.

60. RGB

 

06: 120 min.

70: DVI-D

 

07: 180 min.

90: HDMI (HDMI1)

 

08: 240 min.

C0: Display Port

 

 

 

 

 

 

 

Acknowledgement

91: HDMI2/SDI

 

 

 

 

 

 

 

 

 

 

[f][ ][Set ID][ ][OK/NG][Data][x]

 

 

 

B0:SuperSign

 

 

 

 

 

 

 

 

 

 

 

 

Data1 (Change schedule)

 

 

 

 

 

 

 

 

 

1. f1h to f4h (Read data)

 

 

 

 

 

 

 

 

 

F1: Select the 1st schedule input

 

 

 

 

 

 

 

 

 

F2: Select the 2nd schedule input

 

 

 

 

 

 

 

 

 

F3: Select the 3rd schedule input

 

 

 

 

 

 

 

 

 

F4: Select the 4th schedule input

 

 

 

 

 

 

 

 

 

F5: Select the 5th schedule input

 

 

 

 

 

 

 

 

 

F6: Select the 6th schedule input

 

 

 

 

 

 

 

 

 

F7: Select the 7th schedule input

 

 

 

 

 

 

 

 

 

Data2

 

 

 

 

 

 

 

 

 

20: Input (AV)

 

 

 

 

 

 

 

 

 

40: Component

29. Power On Delay (Command: f h)

60: RGB

To set the schedule delay when the power is turned

70: DVI-D

on. (Unit: Second)

90: HDMI (HDMI1)

 

 

 

 

 

 

 

 

 

 

Transmission

 

 

 

 

 

 

 

C0: Display Port

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[f][h][ ][Set ID][ ][Data][Cr]

 

 

 

 

91: HDMI2/SDI

 

 

 

Data 00 to 64: min. 0 to max. 100 (sec.)

B0:SuperSign

* To read the schedule input, enter FFH for [Data2].

 

 

 

 

 

 

Acknowledgement

If no schedule is available for [Data1] when

 

 

 

 

 

 

 

 

 

 

[h][ ][Set ID][ ][OK/NG][Data][x]

 

 

attempting to read or change the schedule data, the

 

 

 

 

 

 

 

 

 

 

 

text NG will be displayed and the operation fails.

 

 

 

 

 

 

 

 

 

(Example 1: fu 01 60 - Move each schedule input

 

 

 

 

 

 

 

 

 

down one row and save the 1st schedule input in

 

 

 

 

 

 

 

 

 

RGB mode.)

 

 

 

 

 

 

 

 

 

(Example 2: fu 01 f1 ff - Read the 1st schedule

 

 

 

 

 

 

 

 

 

input.)

 

 

 

 

 

 

 

 

 

(Example 3: fu 01 f3 20 - Change the 3rd data

 

 

 

 

 

 

 

 

 

schedule input to the current On Time and AV input.

 

 

 

 

 

 

 

 

 

If there is no third schedule, the text NG will be

 

 

 

 

 

 

 

 

 

displayed and the operation fails.)

 

 

 

 

 

 

 

 

 

* This function is supported only when Time 1 (Year/

 

 

 

 

 

 

 

 

 

Month/Day), Time 2 (Hour/Minute/Second), On Time

30. Automatic Standby (Command: m n)

(Repeat Mode/Time) are set.

To set the Automatic Standby function.

** It may not be supported depending on the model.

 

Transmission

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Acknowledgement

 

 

 

 

 

 

 

 

 

 

[m][n][ ][Set ID][ ][Data][Cr]

 

 

 

 

 

 

 

 

 

 

[u][ ][Set ID][ ][OK/NG][Data][x]

 

 

 

 

 

 

Data 00: Off (No off after 4 hours)

 

 

 

 

[u][ ][Set ID][ ][OK/NG][Data1][Data2][x]

 

 

 

 

 

 

 

 

 

01: 4 Hours (Off after 4 hours)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Acknowledgement

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[n][ ][Set ID][ ][OK/NG][Data][x]

ENGLISH

Page 67
Image 67
LG Electronics 72WX70MF owner manual On Timer Input Command f u Sleep Time Command f f, Power On Delay Command f h