CONTROLLING THE MULTIPLE PRODUCT 71

49. FAN Fault Check (Command: d w)

51. Remote Controller Lock/ Key Lock

 

 

To check the fan errors.

 

(Command: k m)

 

 

 

 

 

 

When the remote control and front keys are locked in

 

Transmission

 

 

 

 

 

 

 

 

 

standby mode, the power cannot be turned on using

 

 

 

 

 

 

 

[d][w][ ][Set ID][ ][Data][Cr]

 

 

 

 

 

the remote control or front power button.

 

Data FF: Read the status

 

 

Transmission

 

 

 

 

 

 

 

 

 

 

 

 

 

Acknowledgement

 

 

 

[k][m][ ][Set ID][ ][Data][Cr]

 

 

 

 

 

 

 

 

 

 

 

[w][ ][Set ID][ ][OK/NG][Data][x]

 

 

 

Data 00: Off (Lock Off)

 

Data 00: Fan fault

 

 

01: On (Lock On)

 

01: Fan OK

* Display will not be turned on by power on key of

 

02: Model without a Fan

remote controller and front panel control keys, if key

 

For 72WX70MF, see the following.

is locked on in standby mode.

 

[w][ ][Set ID][ ][OK/NG][Data1][Data2][x]

 

Acknowledgement

 

 

 

ENGLISH

Data1 00: One or more fans are faulty. 01: All fans are OK.

02: The model has no fan.

Data2 00: No fan is faulty (all fans are OK).

01:1 fan is faulty.

02:2 fans are faulty.

03:3 fans are faulty.

04:4 fans are faulty.

05:5 fans are faulty.

06:6 fans are faulty.

[m][ ][Set ID][ ][OK/NG][Data][x]

**It may not be supported depending on the model.

52.Key (Command: m c)

To send a key code of the IR remote control.

Transmission

[m][c][ ][Set ID][ ][Data][Cr]

Data IR_KEY_CODE

Acknowledgement

[c][ ][Set ID][ ][OK/NG][Data][x]

 

For a key code, see the IR Code.

50. Temperature Value (Command: d n)

* Some key codes are not supported depending on

To check the inside temperature value.

the model.

Transmission

[d][n][ ][Set ID][ ][Data][Cr]

Data FF: Check the status Acknowledgement

[n][ ][Set ID][ ][OK/NG][Data][x]

[n][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][x]

*Temperature is displayed in hexadecimal. Up to Data3 are provided as 72WX70MF has 3 temperature sensors.

Data1: Temperature sensor at the exit (top).

Data2: Temperature sensor at the entrance (bottom).

Data3: Temperature sensor at the main board (main PCB).

53.OSD Select (Command: k l)

To select OSD(On Screen Display) on/off.

Transmission

[k][l][ ][Set ID][ ][Data][Cr] Data 00: Off

01:On

Acknowledgement

[l][ ][Set ID][ ][OK/NG][Data][x]

Page 71
Image 71