Product Specifications
AC module
DC Input
| Parameter | Section | 
 | Value | 
 | |
| Power | Max. | 295 W | 300W | 
 | 305W | 
| Tolerance | 3 % | 3 % | 
 | 3 % | |
| 
 | 
 | ||||
| Voltage | Open Circuit | 39.7 V | 39.8 V | 
 | 40.0 V | 
| Max. Power Point | 31.8 V | 32.0 V | 
 | 32.1 V | |
| 
 | 
 | ||||
| Current | Short Circuit | 9.85 A | 9.98 A | 
 | 10.10 A | 
| Max. Power Point | 9.28 A | 9.40 A | 
 | 9.52 A | |
| 
 | 
 | ||||
| Efficiency | Relative Reduction | 
 | < 2.0% | 
 | 
 | 
| Note : *Relative efficiency reduction in respect to irradiance | 
 | ||||
| 
 | 
 | ||||
Note : Rated electrical characteristics are within 10 percent of above figures.
PV module was measured at STC (Standard Test Condition : Irradiation 1,000W/m2, Cell temp. 77°F(25°C), 1,5AM)
AC Output
| Parameter | 
 | Section | 240VAC | 
 | 208VAC | 
| 
 | 
 | AC Continuous1) | 280W (@DC Module 295W) / 285W (@DC Module | ||
| Power | 
 | 300W) / 290W (@DC Module 305W) | |||
| 
 | 
 | ||||
| 
 | 
 | Inverter Rated Continuous | 305W | 
 | 300W | 
| Voltage | 
 | Rated | 240V (211 ~ 264 V) | 
 | 208V (187 ~ 229V) | 
| Current | 
 | Rated | 1.27A | 
 | 1.44A | 
| 
 | Max. Fault Current | 
 | 77A | ||
| 
 | 
 | 
 | |||
| Efficiency | 
 | Nominal | 60 Hz (59.3 ~ 60.5 Hz) | ||
| 
 | Extended | 57.0 Hz ~ 60.5 Hz | |||
| 
 | 
 | ||||
| 
 | Power Factor | 
 | > 0.95 | ||
| CEC Weighted Efficiency | 96.5% | 
 | 96.0% | ||
| (California Energy Commission) | 
 | ||||
| 
 | 
 | 
 | |||
| Max. Number of AC Modules | 12 ea | 
 | 11ea | ||
1)Pmax (AC) = Max. Input DC Power x CEC Efficiency
Protection
| Ground Fault Detection and Interrupt (GFDI) | Applied | 
| Fuse | 2A | 
| 
 | 
 | 
CAUTION : FOR CONTINUED PROTECTION AGAINST THE RISK OF FIRE,
REPLACE ONLY WITH SAME TYPE AND RATING OF FUSE
Over Current Protection Device (OCPD)
20A
2