Installation
Installation

Select
the
Best Location















































1.To prevent vibration and noise, make sure the unit is installed securely and firmly.
2.Install the unit where the sunlight does not shine directly on the unit.
3.The outside of the cabinet must extend outward for at least 30cm and there should be no obstacles, such as a fence or wall, within 50cm from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.
CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure.
COOLED AIR
75~15cm
AWNING FENCE
HEAT
RADIATION
ABOUT 10~15mm
Over 50cm
Figure 1
4.Install the unit a little slanted so the back is slightly lower than the front (about 10~15mm). This will help force con- densed water to the outside.
5.Install the unit from the bottom about 75~150cm above the floor level.

Installation Check






















































The setting conditions must be checked prior to initial starting.
The following items are especially important checking points when the installation is finished.
1.Grounding wire (Green or Green and Yellow) is provided in the power cord. The green wire must be grounded.
2.Connect to a
3.To avoid vibration or noise, make sure the air conditioner is installed securely.
4 Avoid placing furniture or draperies in front of the air inlet and outlet.
How to Secure the Drain Pipe |
|
| |
In humid weather, excess water may cause the BASE PAN to overflow. To drain |
|
| |
the water, remove the DRAIN CAP and secure the DRAIN PIPE to the rear hole of | Drain pipe |
| |
the BASE PAN. Press the drain pipe into the hole by pushing down and away from |
| ||
the fins to avoid injury. |
| Drain cap | |
Optional |
|
| |
1. Install the drain pan over the corner of the cabinet where you removed the | CABINET | SCREW | |
plug with 4 (or 2) screws. |
|
| |
2. Connect the drain hose to the outlet located at the bottom of the drain pan. | DRAIN | Fig. 1 | |
You can purchase the drain hose or tubing locally to satisfy your particular | DRAIN HOSE | ||
PAN | |||
needs. (Drain hose is not supplied). |
| ||
|
| ||
3. Select the most appropriate connection from among the following figures (by |
| ||
considering the hole of the unit) to fit drain pan to your own unit. |
| Fig. 3 |
Fig. 2
Fig. 4
Service Manual 8