Troubleshooting Guide

Electrical Parts Troubleshooting Guide

Possible Trouble 1

The unit does not operate.

Is the Trans output power

NO

 

 

 

 

 

 

• Check the Fuse.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Check the wiring diagram.

 

AC 220V?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

NO

 

 

 

 

Is the Trans output power

Is shorted the Trans. output?

 

 

• Check the Main

 

 

 

 

 

 

 

about AC 14V?

 

 

 

 

 

 

 

PCB pattern.

 

 

YES

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Exchange the Trans.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is output Voltage of IC01D

NO

 

 

 

 

 

 

• Exchange D02D~D05D.

 

 

 

 

 

 

 

• Exchange IC01D.

 

DC 12V?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

Is output Voltage of IC02D

 

 

 

 

 

 

• Exchange IC02D.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC 5V?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the reset circuit all right?

NO

(The No.16 of

 

Micom is 5V.)

 

 

YES

 

 

 

 

 

 

Is the

connection between NO Main and Display

all right?

YES

NO

Is the voltage No.20 of Micom

DC 5V?

• Exchange IC01A, C02A.

Connect connector exactly.

Check the PCB pattern.

YES

Exchange Main PCB Ass'y.

Service Manual 28