Disassembly
6. Shroud
1. Remove the fan. (Refer to section 21)
2. Remove the screw that fastens the shroud.
3. Remove the shroud. (See Figure 24)
4.
Figure 24
Electrical Parts
7. Motor
1. Remove the cabinet. (Refer to section 18)
2. Remove the cover control and disconnect a wire housing in control box. (Refer to section 19)
3. Remove the blower. (Refer to section 21)
4. Remove the fan. (Refer to section 22)
5. Remove the 4 screws which fasten the motor. (See Figure. 25)
6. Remove the motor.
7.
removal procedure, above.
Figure 25
8.Compressor
1.Remove the cabinet. (Refer to section 18)
2.Discharge the refrigerant system using FreonTM Recovery System.
If there is no valve to attach the recovery system, install one (such as a WATCO
| the FreonTM . Leave the valve in place after |
| |
| servicing the system. |
| |
3. | Disconnect the 3 leads from the compressor. |
| |
4. | After purging the unit completely, unbrace the suc- |
| |
| tion and discharge tubes at the compressor con- |
| |
| nections. |
| |
5. | Remove the 3 nuts and the 3 washers which fas- |
| |
| ten the compressor. | Figure 26 | |
6. | Remove the compressor. (See Figure 26) | ||
|
7.
17Room Air Conditioner