| Troubleshooting Guide |
|
|
|
|
|
COMPLAINT | CAUSE | REMEDY |
|
|
|
|
|
Compressor cycles | Capacitor | Test capacitor. |
|
on overload. |
|
|
|
Wiring | Check the terminals. If loose, repair or replace. |
| |
|
|
|
|
| Refrigerating system | Check the system for a restriction. |
|
|
|
|
|
Insufficient cooling or heat- | Air filter | If restricted, clean of replace. |
|
ing | Exhaust damper door | Close if open. |
|
| Unit undersized | Determine if the unit is properly sized for the area to |
|
|
| be cooled. |
|
Excessive noise. | Turbo or fan | Check the set screw or clamp. If loose or missing, |
|
|
| correct. If the blower or fan is hitting air guide, |
|
|
| rearrange the air handling parts. |
|
|
|
|
|
| Copper tubing | Remove the cabinet and carefully rearrange tubing |
|
|
| not to contact cabinet, compressor, shroud, and bar- |
|
|
| rier. |
|
Auto | Rotary switch. | Set the knob to HIGH COOL or LOW COOL while |
|
|
| rocker switch is ON. |
|
|
|
|
|
| Wiring | Check terminals. If loose, repair or replace. |
|
|
|
|
|
| Synchronous motor. | Check the synchronous motor for open circuit. |
|
|
|
|
|
Service Manual 34