Disassembly
RefrigeratingCycle
CAUTION: Discharge the refrigerant system using a FreonTM Recovery
System. If there is no valve to attach the recovery system, install one (such as a WATCO
13. Condenser
1.Remove the cabinet. (Refer to section 18)
2.Remove the 4 screws that fasten the brace.(Refer to section 20)
3.Remove the 5 screws that fasten the condenser and shroud.
4.After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections.
5.Remove the condenser.
6.
14. evaporator
1.Remove the cabinet. (Refer to section 18)
2.Remove the 2 screws that fasten the evaporator.
3.Move the evaporator sideways carefully. (Refer to section 20)
4.After discharging the refrigerant completely, unbraze the interconnecting tube at the evaporator connections.
5.Remove the evaporator.
6.
15. Capillary Tube
1.Remove the cabinet. (Refer to section 18)
2.After discharging the refrigerant completely, unbraze the interconnecting tube at the capillary tube.(See caution above)
3.Remove the capillary tube.
4.
Figure 31
Figure 32
19Room Air Conditioner