Troubleshooting Guide

Possible Trouble 6 Remote controller does not operate.

Is the voltage of Battery

NO

about over 2.3V?

 

 

YES

 

 

 

Is the voltage No.16

NO

of CN-DISP on Main PCB

 

Ass'y DC 5V?

 

 

YES

 

 

 

Is the connection of

NO

CN-DISP all right?

 

YES

• Exchange Receiver Ass'y.

• Exchange the battery.

• Check the PCB pattern.

Connect connector to CN-DISP exactly.

Possible Trouble 7 It displays abnormally on display PCB Ass'y.

NO

Is the IC01G all right?

 

YES

 

 

NO

 

Is the connection of

NO

CN-DISP all right?

 

 

YES

 

 

 

Does the

NO

Q01G~Q04G operate normally

 

on main PCB Ass'y?

 

YES

Exchange the display PCB Ass'y.

• Exchange IC01G.

• Connect connector to CN-DISP exactly.

• Exchange Q01G-Q04G.

31Room Air Conditioner

Page 32
Image 32
LG Electronics WG1805RY6, WG2405RY6, RAD-183A, RAD-243A service manual Possible Trouble 6 Remote controller does not operate