Manuals
/
Brands
/
Computer Equipment
/
Power Supply
/
Liebert
/
Computer Equipment
/
Power Supply
Liebert
GXT2-10000RT208 user manual
- page 2
1
2
56
56
Download
56 pages, 2.51 Mb
DISCONTINUED
PROD U C T
Contents
Main
Page
TABLE OF CONTENTS
Page
Page
FIGURES
TABLES
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
!WARNING
!CAUTION
1.0 GLOSSARY OF SYMBOLS
!
i
2.0 INTRODUCTION AND SYSTEM DESCRIPTION
3.0 SYSTEM DESCRIPTION
3.1 Transient Voltage Surge Suppression (TVSS) and EMI/RFI Filters
3.2 Rectifier/Power Factor Correction (PFC) Circuit
3.3 Inverter
3.4 Battery Charger
3.5 DC to DC Converter
3.6 Battery
3.7 Static Bypass
4.0 MAJOR COMPONENTS
4.1 Main Frame and Electronics
4.2 Internal Battery Pack
Major Components
8
4.3 Input/Output Terminal Blocks and Optional Output Distribution
INPUT
Figure 4 Optional output distribution modules
L1 N L2NL1 L2 OUTPUT
H-POTED PASS
5.0 WHATS INCLUDED
6.0 INSTALLATION AND CONFIGURATION
6.1 Install the Main Cabinet
6.1.1 Tower UPS Installation
Attach Bezels to Top
6.1.2 Installing the Adjustable Rack-Mount KitSold Separately
!
6.2 External Battery Cabinet Installation
6.3 Connect Input/Output Power
6.3.1 Distribution Module Electrical Connections
UPS
6.3.2 Input & Output Terminal Block Connections
6.3.3 Add an Output Power Distribution ModuleOptional
6.4 Install the Internal Battery Packs
7.0 INITIAL STARTUP AND ELECTRICAL CHECKS
7.1 Hardwire Input Connections
7.2 Output Receptacle Distribution Options
8.0 CONFIGURATION PROGRAM
8.1 Liebert GXT2-10000RT208 Configuration Program Features
8.2 What You Will Need
8.3 Configuration ProgramInstallation
8.4 Establishing Communication Link with the UPS
8.5 Configuration ProgramOperation
8.5.1 Read/Confirm UPS Configuration Settings
8.5.2 Cancel Without Changing UPS Settings
8.5.3 Changing UPS Settings
8.5.4 On-Screen Reminders
8.5.5 Programming Rejected When UPS is Off
Partial Rejection
8.6
8.6.1 Output Voltage
Output Voltage Selection Notes
8.6.2 L-N Reverse Detection120V UPS Models Only
8.6.3 Frequency Selection
8.7 Options Tab
8.8
8.9
8.9.1 Low Battery Time Warning
8.9.2 Auto Battery Test Time
8.9.3 Battery Cabinets Number
8.9.4 Auto Battery Test
Page
9.0 CONTROLS AND INDICATORS
9.1 ON/Alarm Silence/Battery Test Button
9.2 OFF/Bypass Button
Page
10.0 MODES OF OPERATION
10.1 Normal Mode Operation
10.2 Battery Mode Operation
10.3 Battery Recharge Operation
11.0 C
11.1 Communications Interface Port
11.1.1 DB-9 Interface Port
11.1.2 CommunicationsLiebert SNMP/OCWEBCARD SNMP Adapter
11.2 Pin 4 - Remote Shutdown on Battery
11.3 UPS Intelligent Communications
11.4 Remote Emergency Power Off
12.0 M
12.1 Battery Replacement
12.1.1 Internal Battery Replacement Procedures
12.2 UPS Power Module Replacement
Figure 10 UPS back panelcontrol location
Figure 11 Power module replacement
13.0 T
Table 3 Fault indicators Indicator status Diagnosis/Audible alarm
Page
Table 5 Troubleshooting guide Problem Cause Solution
Table 5 Troubleshooting guide (continued) Problem Cause Solution
Page
13.1 Auto-Learning Battery Run Times
14.0 S
Table 7 UPS specifications
Table 8 Battery specifications
Table 9 Optional output distribution specificationsPD-101
Table 7 UPS specifications (continued)
Table 10 Optional output distribution specificationsPD-102
Table 11 Optional output distribution specificationsPD-103
Table 12 Replacement 10kVA power module specifications Model Number GXT2-10KPWR208
14.1 Product Warranty Registration
Page
Page
Ensuring The High Availability 0f Mission-Critical Data And Applications.
Technical Support / Service
Locations