5.5Using the Configuration Tool

Operation

5.5Using the Configuration Tool

The Configuration tool allows users to set up breakers and view or change their parameters and alarm setpoints.

NOTE

End users are unable to create a configuration file. Only Emerson Network Power technical personnel can create a unique configuration file. Please contact your local Emerson Network Power representative or call Liebert Services at 1-800-LIEBERT (1-800-543-2378) for assistance.

5.5.1Starting the Configuration Program

Before starting the Configuration tool, make sure you have the most recent version of the software and decide whether you want to connect to the Liebert LDM or work in offline mode.

Offline mode allows you to run the configuration tool without being connected to the equipment. (Prior to Version 25—LDM-Config-25—a service terminal connection was required to configure or monitor the Liebert LDM.)

NOTE

A configuration file is required for Offline Mode. If one is not available, connect to the equipment locally and save the configuration to disk. See 5.5.4 - Install Configuration Changes in the Unit and 5.5.5 - Save the Configuration File to Disk.

To Connect via COM Port

To Work in Offline Mode

1.

If needed, download the latest version of the

1.

If needed, download the latest

 

software (see 5.3 - Downloading the

 

version of the software (see 5.3 -

 

Software).

 

Downloading the Software).

2.

Connect a PC to the Liebert LDM via the external

2.

Run the file LDM-Config-xx.exe

 

DB9 connection. Refer to 5.2.1 - LDM Setup

 

(where xx is the version number) to

 

Port Connection.

 

start the Configuration program.

3.

Run the file LDM-Config-xx.exe(where xx is

3.

In the Connect window, click the

 

the version number) to start the Configuration

 

Work Offline button, shown below.

4.

program.

4.

When prompted for the

In the Connect window, select the appropriate

 

configuration file, navigate to the

 

COM port from the list of available ports.

 

location of the file.

5.

Click Connect.

5.

Click Open.

 

 

 

 

COM port

Work Offline

 

Proceed to 5.5.2 - Main Configuration Window Overview to begin configuration.