6.6CLEANING THE WAX NOZZLE

The MESSAGE CENTER periodically displays a wax reminder message, if the WAX REMINDER setting is enabled in the MANAGER’S CONFIGURATION. When this message appears, take the following steps:

A.Remove panel on right side to access nozzle (A).

B.Make sure that the unit is off, and the electrical plug has been removed from the wall.

C.Using a Phillips head screwdriver remove the two screws holding the right access panel in place.

D.Carefully reach inside and while gently pushing the nozzle (A) into its brass holder body (C), rotate the nozzle one-quarter turn clockwise. Make note of the orientation of the two flat sur- faces on the top and bottom of the nozzle. When the nozzle is replaced after cleaning, the flats must be on the top and bottom for nozzle to be correctly replaced.

E.Place the nozzle in a container of hot water and let it sit for 10 minutes. Afterward, carefully remove the nozzle.

CAUTION: If necessary, scrub with a medium soft bristle brush until there is no further wax visible on the outside or inside of the nozzle.

F.Dry the nozzle with a lint-free towel and re-insert with a quarter-turn counterclockwise.