TROUBLESHOOTING THE TREADMILL (CONTINUED)

Malfunction

Probable Cause

Corrective Action

 

 

 

Unit resets randomly or

Insufficient power source.

Plug treadmill into a dedicated

pauses

 

20 amp circuit.

 

 

 

 

Damaged ground prong on

Replace line cord.

 

line cord.

 

 

 

 

 

Line cord improperly seated in

Inspect power connection at

 

electrical outlet.

electrical outlet and at

 

 

machine for proper contact.

 

 

 

 

Emergency stop magnet not

Re-engage the emergency

 

engaged.

stop magnet.

 

 

 

 

Towel or other item may be

Move all possible obstructions

 

making contact with stop

off display console and

 

switch while user is running.

handlebar.

 

 

 

 

Towel or other item may be

Move all possible obstructions

 

covering the Smart Stop

off display console and

 

Sensor.

handlebar.

 

 

 

 

Stop switch is activated with

Contact Life Fitness

 

very light pressure or returns

Customer Support Services*.

 

slowly after being pressed.

 

 

 

 

 

Stop switch cable not making

Contact Life Fitness

 

proper contact.

Customer Support Services*.

 

 

 

 

Pinched main wire harness.

Contact Life Fitness

 

 

Customer Support Services*.

 

 

 

 

Open ground path.

Contact Life Fitness

 

 

Customer Support Services*.

 

 

 

 

Inspect Smart Stop system.

Contact Life Fitness

 

 

Customer Support Services*.

 

 

 

* See Section 6.7 “How to Obtain Product Service” for contact information.