Lifebreath RNC20 Engineering Data - HRV, Model RNC155, DIMENSIONS RNC155, Date, Tag Qty, Project

Models: RNC155 RNC20 RNC95 RNC120D RNC10 RNC200 RNC5-TPD

1 36
Download 36 pages 54.76 Kb
Page 5
Image 5
Model RNC155

Engineering Data - HRV

Model RNC155

 

 

THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE

The cross-flow heat recovery core transfers heat between the two air streams.

It is easily removed for cleaning or service.

MOTORS AND BLOWERS

Each air stream has one centrifugal blower driven by a common PSC motor. 2 speed fan operation.

FILTERS

Washable air filters in exhaust and supply air streams.

MOUNTING THE HRV

Four threaded inserts at corners of case designed to accept four reinforced polyester straps that are supplied with the unit.

DEFROST

Recirculating damper defrost system.

CASE

Twenty gauge prepainted galvanized steel (G60) for superior corrosion resistance. Insulated to prevent exterior condensation. Drain connections two - 1/2" (12mm) OD.

WEIGHT 71 lbs. (32.5 kg) SHIPPING WEIGHT 73 lbs. (33.5 kg)

CONTROLS - HRV System Control

HRV defaults to LOW SPEED when plugged in. HIGH SPEED option is accessible by connecting remote controls to designated terminals inside electrical box of HRV.

Standard LOW SPEED SETTING can be increased to medium low.

Off (Standby)/Low or OFF/HIGH speed operation is also available.

OPTIONAL MAIN CONTROLS (only one main control can be installed on the system)

99-116

Dehumidistat Ventilation Control - Dehumidistat Dial, ON/OFF Switch and

 

LOW/HIGH Switch (3 wire) 20 gauge wire (min.) 100' length (max.)

99-2040

20/40 ON/OFF Dehumidistat - Dehumidistat Dial, ON/OFF Switch and 20/40 Switch.

 

The 20/40 Switch will toggle from continuous low speed ventilation to intermittent low

 

speed ventilation of 20 minutes fan ON and 40 minutes fan OFF. (4 wire) 20 gauge wire

 

(min.) 100' length (max.)

99-RECIRC

Recirculation Control - Dehumidistat Dial, ON/OFF Switch and Recirculation Switch.

 

The Recirculation Switch will toggle from continuous low speed ventilation to continuous

 

low speed recirculation. (4 wire) 20 gauge wire (min.) 100' length (max.)

99-130

Remote Dehumidistat - Dehumidistat Dial only. (2 wire) 20 gauge wire (min.) 100'

 

length (max.)

OPTIONAL TIMERS

99-132

20 Minute Fan Timer - initiates high speed ventilation for 20 minutes. (3 wire) 20 gauge

 

wire (min.) 100’ length

99-104

Digital Electronic Timer- initiates high speed ventilation for 20, 40 or 60 minutes, (3

 

wire) 20 gauge wire (min.) 100' length

99-101

60 Minute Crank Timer - initiates high speed ventilation for up to 60 minutes, (2 wire)

 

20 gauge wire (min.) 100' length (max.)

WARRANTY

Units carry a lifetime warranty on the heat recovery core and a 5 year replacement parts warranty.

Performance (HVI certified)

Net supply air flow in cfm (L/s) against external static pressure

E.S.P

 

 

(external static pressure)

[cfm (L/s)]

@ 0.1" (25 Pa)

150

(71)

@ 0.2" (50 Pa)

146

(69)

@ 0.3" (75 Pa)

134

(63)

@ 0.4" (100 Pa)

121

(57)

@ 0.5" (125 Pa)

106

(50)

@ 0.6" (150 Pa)

92

(43)

Max. Temperature Recovery

78%

 

 

 

Sensible Effectiveness

 

 

@ 65 cfm (31 L/s)

32°F (0°C)

76%

*Sensible Efficiency

 

 

@ 65 cfm (31 L/s)

32°F (0°C)

64%

*Sensible Efficiency

 

 

@ 68 cfm (32 L/s)

-13°F (-25°C)

66%

VAC @ 60HZ

 

120

WATTS / Low speed.

 

49

WATTS / High speed

 

120

Amp rating

 

1.4

*Sensible Efficiency – thermal **Latent Efficiency – moisture Note: Effectiveness - based on temp. differential between the 2 airstreams Efficiency – takes into account all power inputs

 

160

 

 

 

 

3 - High Speed

 

 

 

 

 

 

 

 

 

 

3

 

 

 

*2 - Medium Low Speed

 

 

140

 

 

 

 

*1 - Low speed

 

 

 

 

 

 

 

 

 

 

120

 

 

 

 

* Manufacturers Data

 

 

 

 

 

 

 

 

 

Flow (cfm)

100

 

 

 

 

 

 

 

80

 

 

 

 

 

 

 

Air

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

Static Pressure (in w .g.)

All units conform to CSA and UL standards

DIMENSIONS RNC155

inches (mm)

FRESH AIR

STALE AIR

FROM INSIDE

FROM OUTSIDE

 

RECIRCULATING

FILTERS

 

DEFROST

 

DAMPER

 

CORE

BLOWERS

MOTOR

 

STALE AIR

FRESH AIR

TO OUTSIDE

TO INSIDE

 

33 5/8"

CONDENSATE DRAINS

(850mm) BALANCING DAMPER

19"

(483)

*NOTE: Front clearance of 25 inches (635 mm) is recommended for servicing unit.

*All Duct Connections 6" (150mm)

143/4"

(375)

Date: _______________________________________________

Contractor: __________________________________________

Tag: __________________________Qty:__________________

Supplier: ____________________________________________

Project: _____________________________________________

Quote#: _____________________________________________

Engineer:____________________________________________

Submitted by: ________________________________________

5

SP-RNC155

 

Page 5
Image 5
Lifebreath RNC5-TPD, RNC200, RNC10, RNC95 Engineering Data - HRV, Model RNC155, DIMENSIONS RNC155, Date, Tag Qty, Project