OPERATION | ||
|
|
|
Display Control Keys
The function select, timer/crater select, arrow keys and rotational encoders all effect the display. Pressing the function select key will cause a function to be displayed. Pressing the timer/crater select key will cause a timer or crater feed speed to be displayed. Whichever is pressed last is the one that will be displayed since they cannot be displayed simultaneously. Only one function or timer indicator light can be on at one time and therefore it always indicates what is being displayed. The arrow keys allow you to adjust the
Note: If an indicator light is skipped, that parameter may not be enabled. Refer to section covering that parameter.
Function Select key enables oper- V VOLTS / TRIM ator to choose which function will
be displayed as indicated by the
appropriate light. Pressing the key causes lights to sequence (top to
WFS
bottom) starting from the current indicated position. If a timer or crater speed is being displayed when the Function Select key is pressed, then the indicator light of the last function selected before the timer/crater key was chosen will come on and become the starting point for the sequencing.
Adjusting either encoder knob automati- cally transfers display (and indicator light) to the function being adjusted (Volts/Trim or Wire Feed Speed).
Top Light - indicates Voltmeter Function has been selected and arc voltage (in volts) will be displayed along with electrode polarity when the trigger has been pressed. When the trigger is not pressed, this will serve as a preset voltage/trim function and the preset voltage/trim will be displayed. The top light “blinks” when arc voltage is being displayed and stays lit when preset voltage/trim is displayed. The last welding voltage displayed before the weld is stopped, will con- tinue to be displayed for 5 seconds
SYNERGIC 7F & FH
after welding to permit operator monitoring. The preset voltage/trim may be adjusted, using the Volts/Trim encoder knob. The syn- ergic preset voltage/trim level may be adjust- ed within the range synergically set by the power source for the process and weld Feed Speed being used. The power source auto- matically determines whether preset volt- age or percent trim will be displayed. Preset voltage is indicated by one digit only to the right of the decimal point, while per- cent trim always displays two digits to the right of the decimal point.
Middle Light - Indicates
As shipped these models are setup for minimum rated fixed
Wire will be fed at the
The
Bottom Light - Indicates Weld Feed Speed (WFS) Function has been selected and the weld speed setting is being dis- played in IPM or m/m (see section for English or Metric speed display). The range of Weld Feed Speed is synergically set by the power source for the process being used, and is adjustable using the Wire Feed Speed encoder knob on the front of the Synergic 7F Control.
If selected (see Memory Ammeter Selection section), the bottom light will “blink” while welding, indicating that the dis- play has been selected to display welding amps. The last welding current displayed before the weld is stopped will continue to be displayed for 5 seconds after welding to permit operator monitoring.