E-2

TROUBLESHOOTING

E-2

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

1. Rough wire feeding or wire not

a. Gun cable kinked and/or twisted.

a. Inspect gun cable and replace if

feeding but drive rolls turning.

 

necessary.

 

b. Wire jammed in gun and cable.

b. Remove wire from gun and cable

 

 

feed in new wire. Note any

 

 

obstructions in gun and cable.

 

 

Replace gun and cable if neces-

 

 

sary.

 

c. Incorrect position of drive rolls with

c. See Wire Feed Drive Roll and

 

grooves.

Guide Tubs Kits section for proper

 

 

installation of drive roll.

 

d. Drive rolls loose.

d. Remove, clean, install and tighten.

 

e. Gun cable dirty.

e. Clean cable or replace liner.

 

f. Worn drive roll.

f. Replace.

 

g. Electrode rusty and/or dirty.

g. Replace.

 

h. Worn nozzle or cable liner.

h. Replace.

 

i. Partially flashed or melted contact tip.

i. Replace contact tip.

 

j. Incorrect idle roll pressure.

j. Set idle roll pressure per section

 

 

on Idle Roll Pressure Setting.

 

k. Improper liner, tip or guide tube.

k. Install proper equipment.

 

 

 

 

2. Variable or “hunting” arc.

a. Wrong size, worn and/or melted

a. Replace tip - remove any spatter

 

contact tip.

on end of tip.

 

b. Worn work cable or poor work

b. Inspect - Repair or replace as

 

connection.

necessary.

 

c. Loose electrode connections.

c. Be sure electrode lead is tight in

 

 

wire feeder contact block, gun

 

 

nozzle and gun tip tight.

 

d. Wrong polarity.

d. Check connection at output studs

 

 

for polarity required by welding

 

 

process.

 

e. Problem with serial communica-

e. Make sure control cable connections are

 

tions in control cable.

tight. Check for consistent WFS. Make sure

 

parameters on Power Source display, such

 

 

 

 

as WFS, match those on wire feeder display,

 

 

if not, try changing Synergic 7F control board.

 

 

If problem persists refer to Power Source

 

 

trouble shooting information.

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

SYNERGIC 7F & FH

Page 31
Image 31
Lincoln Electric IM559 manual Replace contact tip, Tions in control cable, Trouble shooting information