E-11

TROUBLESHOOTING

E-11

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

25.Display shows any of the follow- ing:

 

 

HI

a. Voltmeter function is selected and a. Normal operation. Voltmeter only

 

 

 

 

arc voltage is > 80 VDC.

reads 0-80 VDC.

 

 

 

 

 

 

 

 

---

a. Run-in speed is selected but is

a. Run-in speed is now = weld speed.

 

 

 

 

disabled.

To re enable Run-in speed simply

 

 

 

 

 

press the increase arrow key.

 

 

 

 

 

 

 

 

 

HXX

a. See Problem 5 or see Section on

a. XX indicates time in seconds before

 

 

 

 

Safety Precautions.

unit will automatically reset.

 

 

 

 

 

 

 

 

 

Er

a. EEPROM error.

a. Parameter recalled at power-up was

 

 

 

 

 

out of range. Press any key to reset.

 

 

 

 

 

Check all settings before proceeding

 

 

 

 

 

to weld. If this condition persists then

 

 

 

 

 

ROM assembly X8 on the Control PC

 

 

 

 

 

board is faulty. Replace Control PC

 

 

 

 

 

board. (See procedure for replacing

 

 

 

 

 

PC boards.)

 

 

 

 

 

 

 

 

 

EXX

a. Where XX is a number from 1 to

a. Turn off power to feeder. Wait for 5

 

 

 

 

10. System error.

seconds. Turn power back on. If EXX

 

 

 

 

 

is displayed again then ROM assem-

 

 

 

 

 

bly X8 on the Control board is faulty.

 

 

 

 

 

Replace Control PC board. (See pro-

 

 

 

 

 

cedure for replacing PC boards.)

 

 

 

 

 

 

 

 

 

EP

a. EPROM checksum error.

a. Turn off power to feeder. Wait 5 sec-

 

 

 

 

 

onds. Turn power back on. If EP is

 

 

 

 

 

displayed again then ROM assembly

 

 

 

 

 

X8 on Control PC board is faulty.

 

 

 

 

 

Replace Control PC board. (See pro-

 

 

 

 

 

cedure for replacing PC boards.)

 

 

 

 

 

 

 

 

 

uP

a. Microprocessor RAM error.

a. Turn off power to feeder. Wait 5 sec-

 

 

 

 

 

onds. Turn power back on. If uP is

 

 

 

 

 

displayed again then ROM assembly

 

 

 

 

 

X8 on the Control PC board is faulty.

 

 

 

 

 

Replace Control PC board. (See pro-

 

 

 

 

 

cedure for replacing PC boards.)

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

SYNERGIC 7F & FH

Page 40
Image 40
Lincoln Electric IM559 manual See Problem 5 or see Section on, Cedure for replacing PC boards Eprom checksum error