B-9

 

OPERATION

B-9

 

 

 

 

Explanation of Prompting and

 

Error Messages

 

Display

Prompt or Error

 

HI

Indicates arc voltage is above 80V DC.

 

---Indicates selected Run-In speed will be the same as the weld speed. To enter a different Run-In speed simply press the increase arrow key with Run-In selected.

HXX

Indicates wire feed overload. XX indicates

 

time remaining in seconds before unit resets

 

automatically. See sections on Routine

 

Maintenance, Periodic Maintenance, and

 

Troubleshooting Guide Problem 25.

EP

Indicates problem in EPROM assembly. See

 

Troubleshooting Guide Problem 25.

uP

Indicates problem in microprocessor RAM.

 

See Troubleshooting Guide Problem 25.

EXX

Indicates various system problems. XX will

 

be a number from 01 to 10. Turn off power to

 

feeder. Wait 5 seconds. Turn power back on.

 

If error persists, see Troubleshooting Guide

 

Problem 25. If error does not reoccur, be

 

sure to check all wire feed speed, accelera-

 

tion, and timer settings before you proceed.

Er

EEPROM error. Usually occurs at power-up.

 

Indicates one or more of the recalled settings

 

is out of acceptable limits. Press any key to

 

return to normal operation. Be sure to check

 

all wire feed speed, acceleration, and timer

 

settings before you proceed.