E-6

TROUBLESHOOTING

E-6

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

12. Arrow keys do not change Weld

a. This is normal, as only the WFS and

a. Refer to operation section of this manual

speed or volts/trim.

volts/trim knobs will adjust these settings.

 

 

 

 

13. WFS knob does not change

a. This is normal, as only the arrow

a. Refer to operation section of this manual.

Run-in speed.

keys will adjust this setting.

 

 

 

 

14. WFS and preset Volts/Trim para-

a. Power source is defective.

a. If parameters on power source and wire

meters on wire feeder display do

 

feeder display match when wire feeder is

not match those on power

 

connected to the other input receptacle (#1

source display.

 

or #2) of power source then power source

 

 

is defective.

 

b. Problem with serial communica-

b. Disconnect input cable from power source

 

tions in control cable.

and wire feeder. Check continuity between

 

 

socket G of 8-socket plug and pin G of 14

 

 

pin plug of the input cable. Check continu-

 

 

ity between socket H of 8-socket plug and

 

 

pin H of 14-pin plug of the input cable.

 

 

Replace cable if no continuity.

 

c. Problem with wire feeder harness

c. Remove molex plug P5 from J5 on Control

 

or Control PCB.

PCB. Check continuity from pin G of 8-pin

 

 

receptacle on wire feeder to pin 5 of plug

 

 

P5, and from pin H of 8-pin receptacle to

 

 

pin 6 of plug P5. If no continuity then repair

 

 

harness, otherwise replace Control PCB.

 

 

(See procedure for replacing PC boards.)

 

 

 

15. Display does not change when

a. A remote control kit is connected.

a. When a remote control kit is connected to

WFS and/or Volts/Trim knobs

 

the Control Box, the WFS and Volts/Trim

are turned.

 

knobs of the Control Box become inactive

 

 

and the WFS and Volts/Trim knobs of the

 

 

remote control kit must be used.

 

b. Broken harness wire(s) or harness

b. Check for continuity between correspond-

 

disconnected from Encoder

ing harness leads of molex plug P1 on

 

board(s) or Control board.

Control board and molex plugs P17 and

 

 

P18 on Encoder boards (refer to wiring dia-

 

 

gram). If any of these continuity tests fail,

 

 

repair or replace harness.

 

c. Defective Encoder boards and/or

c. If b. is not the problem and neither the WFS

 

Control board.

or Volts/Trim knobs are properly adjusting

 

 

then replace the Control board. If one of

 

 

the knobs is properly adjusting, plug the

 

 

harness, P17 or P18, from the working

 

 

board into the nonfunctional board. If the

 

 

previously nonfunctional board is now work-

 

 

ing then replace the Control board, other-

 

 

wise replace the nonfunctional Encoder

 

 

board. (See procedure for replacing PC

 

 

boards.)

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

SYNERGIC 7F & FH

Page 35
Image 35
Lincoln Electric IM559 Arrow keys do not change Weld, Speed or volts/trim, Meters on wire feeder display do, Is defective