E-9

TROUBLESHOOTING

E-9

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

19. Dual procedure switch of remote

a. Local dual procedure switch is not

a. Local dual procedure switch should be

control kit is not functioning prop-

in "Gun" position, and/or an

in "Gun" position if a remote control kit

erly.

optional gun dual procedure

is attached. If an optional gun dual

 

switch is attached.

procedure switch is attached and both

 

 

the local dual procedure switch and

 

 

remote's dual procedure switch are in

 

 

"Gun" position then the optional gun

 

 

dual procedure switch is used to

 

 

switch between procedures "A" and

 

 

"B".

 

b. Faulty communication between

b. If knobs on remote control kit are not

 

wire feeder and remote control kit.

operating properly, refer to Problem

 

 

16.

 

c. Faulty dual procedure switch,

c. Disconnect harness plug from Remote

 

wiring harness, or PC board in

PC board. Check that there is conti-

 

remote control kit.

nuity between plug pins 7 and 8 when

 

 

dual procedure switch is in position

 

 

"A", but not when in "Gun" or "B".

 

 

Now check that there is continuity

 

 

between plug pins 6 and 7 when dual

 

 

procedure switch is in position "B", but

 

 

not when in "Gun" or "A". If any of

 

 

these tests failed, repair or replace

 

 

switch or switch harness. Otherwise

 

 

replace Remote PC board.

 

 

 

20. Purge key does not turn on sole-

a. Defective keypad or Display PC

a. Check continuity between sockets 5

noid but trigger closure does.

board is defective.

and 1 of keypad connector when

 

 

purge key is closed. If not, then

 

 

replace keypad, otherwise replace

 

 

Display PC board. (See Procedure

 

 

for Replacing PC boards).

 

 

 

21. Cold Feed key does not turn on

a. Defective keypad or Display PC

a. Check continuity between sockets 4

wire feed motor but trigger clo-

board is defective.

and 1 of keypad connector when Cold

sure does.

 

Feed key is closed. If not, then

 

 

replace keypad, otherwise replace

 

 

Display PC board. (See Procedure

 

 

for Replacing PC boards).

 

 

 

22. Display and/or indicator lights do

a. Defective keypad or Display PC

a. Ring out keypad. Replace if defec-

not change when the arrow or

board.

tive. If not, then replace Display PC

select keys are pressed.

 

board. (See Procedure for Replacing

 

 

PC boards).

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

SYNERGIC 7F & FH

Page 38