TROUBLESHOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
|
|
|
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF MISADJUSTMENTS(S)
RECOMMENDED
COURSE OF ACTION
19. Dual procedure switch of remote | a. Local dual procedure switch is not | a. Local dual procedure switch should be |
control kit is not functioning prop- | in "Gun" position, and/or an | in "Gun" position if a remote control kit |
erly. | optional gun dual procedure | is attached. If an optional gun dual |
| switch is attached. | procedure switch is attached and both |
|
| the local dual procedure switch and |
|
| remote's dual procedure switch are in |
|
| "Gun" position then the optional gun |
|
| dual procedure switch is used to |
|
| switch between procedures "A" and |
|
| "B". |
| b. Faulty communication between | b. If knobs on remote control kit are not |
| wire feeder and remote control kit. | operating properly, refer to Problem |
|
| 16. |
| c. Faulty dual procedure switch, | c. Disconnect harness plug from Remote |
| wiring harness, or PC board in | PC board. Check that there is conti- |
| remote control kit. | nuity between plug pins 7 and 8 when |
|
| dual procedure switch is in position |
|
| "A", but not when in "Gun" or "B". |
|
| Now check that there is continuity |
|
| between plug pins 6 and 7 when dual |
|
| procedure switch is in position "B", but |
|
| not when in "Gun" or "A". If any of |
|
| these tests failed, repair or replace |
|
| switch or switch harness. Otherwise |
|
| replace Remote PC board. |
|
|
|
20. Purge key does not turn on sole- | a. Defective keypad or Display PC | a. Check continuity between sockets 5 |
noid but trigger closure does. | board is defective. | and 1 of keypad connector when |
|
| purge key is closed. If not, then |
|
| replace keypad, otherwise replace |
|
| Display PC board. (See Procedure |
|
| for Replacing PC boards). |
|
|
|
21. Cold Feed key does not turn on | a. Defective keypad or Display PC | a. Check continuity between sockets 4 |
wire feed motor but trigger clo- | board is defective. | and 1 of keypad connector when Cold |
sure does. |
| Feed key is closed. If not, then |
|
| replace keypad, otherwise replace |
|
| Display PC board. (See Procedure |
|
| for Replacing PC boards). |
|
|
|
22. Display and/or indicator lights do | a. Defective keypad or Display PC | a. Ring out keypad. Replace if defec- |
not change when the arrow or | board. | tive. If not, then replace Display PC |
select keys are pressed. |
| board. (See Procedure for Replacing |
|
| PC boards). |
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
SYNERGIC 7F & FH