A-5
INSTALLATION
DC-655
A-5
OUTPUT CONNECTIONS
ELECTRODE AND WORK CABLES
Use the shortest possible cable lengths. See Table
A.1 for recommended cable sizes based on length.
The output terminals are located at the lower front of
the welder behind a hinged door Refer to figure A.3.
Route the welding cables through the slotted strain
reliefs of the base to the welding terminals.
LOW INDUCTANCE TERMINAL
On the DC-655, the inside right Negative (-) output
terminal is lower choke inductance. This terminal is
presently only recommended for CV mode welding
with NR203Ni 1% negative polarity procedures. All
other processes are to be welded using the outside
right Negative (-) output terminal with higher choke
inductance. CC mode processes must use high
inductance.
For Positive Polarity:
1. Connect the work cable to the high inductance (-)
terminal (marked " ").
2. Connect the electrode cable to the positive terminal
marked “+”.
3. Remove the terminal strip access cover panel on
the lower case front. Refer to figure A.3 for the
location.
4. Work Sense lead #21 from the 14 Pin MS-recepta-
cle must be connected to “-21”on the terminal strip.
Note: This is how the DC-655 is shipped from
the factory.
5. Replace the terminal strip access cover panel.
For Negative Polarity:
1. Connect the electrode cable to the appropriate high
inductance (-) terminal (marked " ") or
to the low inductance (-) terminal
(marked " ") if using NR203Ni 1% elec-
trode only.
2. Connect the work cable to the positive terminal
marked “+”.
3. Remove the terminal strip access cover panel on
the lower case front. Refer to figure A.3 for the
location.
4. Work Sense lead #21 from the 14 Pin MS-recepta-
cle must be connected to “+21”on the terminal strip.
5. Replace the terminal strip access cover panel.
TABLE A.1
Cable Sizes for Combined Lengths of Copper
Electrode and Work Cable
Cable Length
ft. (m)
Parallel Cables Cable Size
0 (0) to 100 (30.4)
100 (30.4) to 200 (60.8)
200 (60.8) to 250 (76.2)
2
2
2
2/0 ( 70mm2)
3/0 ( 95mm2)
4/0 (120mm2)
POSITIVE
OUTPUT
TERMINAL
LOW INDUCTANCE
NEGATIVE OUTPUT
TERMINAL
HIGH INDUCTANCE
NEGATIVE OUTPU
T
TERMINAL
TERMINAL STRIP
COVER PANEL
14 PIN MS RECEPTACLE
FIGURE A.3 Output Connections