INSTALLATION |
AUXILIARY POWER AND
CONTROL CONNECTIONS
Located at the lower front of the welder behind a hinged door is a 115VAC duplex receptacle for auxil- iary power (Domestic and Canadian Models only) and a 14 Pin MS type receptacle for connection of auxil- iary equipment such as wire feeders. Also, terminal strips with 115VAC and connections for auxiliary equipment are located behind the access panel on the lower case of the welder. A 220VAC receptacle for a water cooler (European and Export Models only) is located on the case back.
AUXILIARY POWER TABLE
Voltage and Circuit Breaker Ratings at Auxiliary Power
Connections for Various Models
Auxiliary | Domestic | Canadian | European | Export | |
Power | Models | Model | Models | Models | |
Connections | (60Hz) | (230/460/575V/60 Hz) | (50/60 Hz) | (50/60 Hz) | |
|
|
|
|
|
|
|
| (Code 10502) | (Code 11300) |
|
|
At Duplex | 115V 20A | 115V 15A | 115V 20A | No Duplex | No Duplex |
Receptacle |
|
|
|
|
|
|
|
|
|
|
|
Terminal strip | 115V 20A | 115V 15A | 115V 20A | 115V 15A | 115V 15A |
terminals 31 & 32 |
|
|
|
|
|
|
|
|
|
|
|
115V 20A | 115V 15A | 115V 20A | Open Circuit | 115V 15A | |
pins A & J |
|
|
|
|
|
|
|
|
|
|
|
42V 10A | 42V 10A | 42V 10A | 42V 10A | ||
pins I & K |
|
|
|
|
|
|
|
|
|
|
|
At 220V | No Receptacle | No Receptacle | 220V 2A | 220V 2A | |
Receptacle |
|
|
|
|
|
|
|
|
|
|
|
115VAC DUPLEX RECEPTACLE (DOMESTIC AND CANADIAN MODELS ONLY)
The 115VAC duplex receptacle is protected by a cir- cuit breaker located below the receptacle (see Auxiliary Power Table). Receptacle is a NEMA
220VAC RECEPTACLE (EUROPEAN AND EXPORT MODELS ONLY)
A Continental European receptacle is located on the rear panel for supplying 220VAC to a water cooler. The receptacle has a protective cover to prevent inci- dently contact and is a Schuko type. The circuit is pro- tected by a 2 amp circuit breaker also located on the rear panel. This circuit is electrically isolated from all other circuits, but on the European Models one line is connected to chassis ground.
14 PIN MS TYPE RECEPTACLE
(For
Refer to the figure A.4 for the available circuits in the 14 pin receptacle.
42 VAC is available at receptacle pins I and K. A 10 amp circuit breaker protects this circuit.
115 VAC is available at receptacle pins A and J (Domestic, Canadian and Export Models). This circuit is protected by a circuit breaker (see Auxiliary Power Table). Note that the 42 VAC and 115 VAC circuits are electrically isolated from each other. However, on the European model one line of the 115VAC is con- nected to chassis ground.
FIGURE A.4 FRONT VIEW OF 14-PIN CONNECTOR RECEPTACLE
|
| K = 4 2 | ||
| A = 3 2 |
|
| J = 3 1 |
| B = G N D |
|
| I = 4 1 |
| L |
|
| N |
|
|
| ||
| C = 2 |
|
| H = 2 1 |
|
|
| ||
|
|
|
| |
| D = 4 |
|
| G = 7 5 |
|
|
|
| |
| E = 7 7 |
|
| F = 7 6 |
|
|
|
| |
|
|
| M | |
|
|
|
|
|
PIN | LEAD NO. |
|
| FUNCTION |
|
|
|
|
|
A | 32 |
|
| 115 VAC |
B | GND |
|
| Chassis Connection |
C | 2 |
|
| Trigger Circuit |
D | 4 |
|
| Trigger Circuit |
E | 77 |
|
| Output Control |
F | 76 |
|
| Output Control |
G | 75 |
|
| Output Control |
H | 21 |
|
| Work Sense Connection2 |
I | 41 |
|
| 42 VAC |
J | 31 |
|
| 115 VAC1. |
K | 42 |
|
| 42 VAC |
L |
| |||
M |
| |||
N |
|
1.115VAC circuit is not present on IEC
2.As shipped from the factory Lead #21 from the 14 Pin connector is connected to