E-7

 

TROUBLESHOOTING

E-7

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

PROBLEMS

POSSIBLE

RECOMMENDED

 

 

(SYMPTOMS)

CAUSE

COURSE OF ACTION

 

 

 

 

 

 

PROBLEMS

Thermal Protection Light comes ON

1.

Check for obstructions that could

and fan does not run.

 

prevent the fan from turning.

NOTE: Fan is thermal controlled and

2.

Check the fan control circuit. See

does not continuously run when

 

wiring diagram.

machine is powered up.

 

 

 

3.

The fan motor may be faulty.

 

4.

The Thermal Fan/Snubber PC

 

 

board may be faulty. See PC

 

 

board LED information.

 

 

 

Fan runs continuously.

1.

The Thermal Fan Thermistor may

 

 

be faulty. See wiring diagram.

 

2.

The Thermal Fan/Snubber PC

 

 

board may be faulty. See PC

 

 

board LED information.

 

 

 

One or both Digital Meters not light-

1.

The meters may not be receiving

ing.

 

the voltages from the auxiliary

 

 

transformer. Check plug P13.

 

 

See wiring diagram.

 

2.

The Digital meter PC board may

 

 

be faulty.

 

 

 

Digital Voltmeter not working proper-

1.

Meter may not be receiving auxil-

ly or erratic display.

 

iary or sensing voltages. Make

 

 

sure plug P12 & P13 are securely

 

 

plugged into the Digital meter PC

 

 

board and also plug P3 is securely

 

 

plugged into the control board.

 

2.

The may be an open in the volt-

 

 

age feedback circuit. See wiring

 

 

diagram.

 

3. The Digital meter PC board may

 

 

be faulty.

 

 

 

Contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

DC-655

Page 33
Image 33
Lincoln Electric IM602-A manual Troubleshooting