Lincoln Electric IM718 manual 7OPERATIONB-7, CV Welding

Models: IM718

1 48
Download 48 pages 8.92 Kb
Page 27
Image 27

B-7OPERATIONB-7

CV WELDING

Synergic CV:

For each wire feed speed, a corresponding voltage is preprogrammed into the machine through special soft- ware at the factory. The nominal preprogrammed volt- age is the best average voltage for a given wire feed speed, but may be adjusted to preference. With syner- gic programs, when the wire feed speed changes the Power Wave will automatically adjust the voltage cor- respondingly to maintain similar arc characteristics throughout the WFS range.

Non Synergic CV:

This type of CV mode behaves more like a conven- tional CV power source. Voltage and WFS are inde- pendent adjustments. Therefore to maintain the arc characteristics, the operator must adjust the voltage to compensate for any changes made to the WFS.

All CV Modes:

Wave control adjusts the inductance of the wave shape. (This adjustment is often referred to as "pinch". Inductance is inversely proportional pinch.) Increasing wave control greater than 0.0 results in a crispier, colder arc while decreasing the wave control to less than 0.0 provides a softer, hotter arc.

(See Figure B.2 for CURRENT WAVE FORM (CV)

FIGURE B.2

Wave Control +10.0

Wave Control 0.00

Current

Wave Control -10.0

Time

POWER WAVE AC/DC

Page 27
Image 27
Lincoln Electric IM718 manual 7OPERATIONB-7, CV Welding