E-4

 

 

 

TROUBLESHOOTING

 

E-4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

 

RECOMMENDED

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Machine often “noodle welds” (out-

 

 

1. Secondary current limit has

 

 

 

 

 

 

 

 

 

 

 

 

 

put is limited to approximately 100

 

 

been exceeded, and the

 

 

 

 

 

 

amps) when running a particular

 

 

machine has phased back to

 

 

 

 

 

 

procedure

 

 

protect itself. Adjust procedure

 

 

 

 

 

 

 

 

 

 

or reduce load to lower cur-

 

 

 

 

 

 

 

 

 

 

rent draw from the machine.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary receptacle is “dead” — no

 

 

1. Circuit breaker CB2 (on case

 

 

 

 

 

 

auxiliary voltage .

 

 

front) may have opened.

 

 

 

 

 

 

 

 

 

 

Reset.

 

 

 

 

 

 

 

 

 

 

2. Circuit breaker CB4 (in recon-

 

 

 

 

 

 

 

 

 

 

nect area) may have opened.

 

 

 

 

 

 

 

 

 

 

Reset.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The Power Wave is triggered to

 

 

1. Check for fault signals from

 

 

 

 

 

 

weld, but there is no output.

 

 

the I/O connector. Possible

 

 

 

 

 

 

 

 

 

 

faults are lack of water flow

 

 

 

 

 

 

 

 

 

 

2. Circuit breaker CB4 (in recon-

 

 

 

 

 

 

 

 

 

 

nect area) may have opened.

 

 

 

 

 

 

 

 

 

 

Reset.

 

 

 

 

 

 

 

 

 

 

 

 

 

If all recommended possible areas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of misadjustments have been

 

 

 

 

 

 

 

 

 

 

checked and the problem persists,

 

 

 

 

 

 

 

 

 

 

contact your local Lincoln

 

 

 

 

 

 

 

 

 

 

Authorized Field Service Facility.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electric Field Service Facility for technical assistance.

POWER WAVE AC/DC

Page 34
Image 34