Safety Instructions

Operating Instructions

Troubleshooting Tips

Consumer Support

Before you call for service…

Troubleshooting Tips

Save time and money! Review the charts on the following pages, or visit GEAppliances.com. You may not need to call for service.

PROBLEM

Possible Causes

What To Do

Dryer shakes or

Some shaking/noise is normal.

• Move dryer to an even floor space, or adjust leveling legs

makes noise

Dryer may be sitting unevenly

as necessary until even.

 

 

 

Clothes take too long

Improper or obstructed ducting

• Check the Installation Instructions to make sure the

to dry

 

dryer venting is correct.

 

 

• Make sure ducting is clean, free of kinks and

 

 

unobstructed.

 

 

• Check to see if outside wall damper operates easily.

 

 

 

 

Improper sorting

• Separate heavy items from lightweight items (generally,

 

 

a well-sorted washer load is a well-sorted dryer load).

 

 

 

 

Large loads of heavy fabrics

• Large, heavy fabrics contain more moisture and take

 

(like beach towels)

longer to dry. Separate large, heavy fabrics into smaller

 

 

loads to speed drying time.

 

 

 

 

Controls improperly set

• Match control settings to the load you are drying.

 

 

 

 

Lint filter is full

• Clean lint filter before every load.

 

 

 

 

Blown fuses or tripped circuit

• Replace fuses or reset circuit breakers. Since most

 

breaker

dryers use 2 fuses/breakers, make sure both are

 

 

operating.

 

 

 

 

Overloading/combining loads

• Do not put more than one washer load in the dryer at

 

 

a time.

 

 

 

 

Underloading

• If you are drying only one or two items, add a few items

 

 

to ensure proper tumbling.

 

 

 

The DRY dryness level

Load consists of a mixture

• When combining heavy and light fabrics in a load,

was chosen but load is

of heavy and light fabrics

choose MORE DRY.

still damp

 

 

 

 

 

 

Exhaust system is blocked

• Inspect and clean exhaust system.

 

 

 

Control pads not

Controls accidentally put in

• Press START/PAUSE.

responding

service mode

 

 

 

 

 

Controls accidentally put in

• Hold the LOCK button for 3 seconds to unlock the dryer.

 

lock mode

 

 

 

 

 

Controls performed an

• Reset the in-house breaker.

 

incorrect operation

 

 

 

 

Dryer doesn’t start

Control panel is “asleep”

• This is normal. Press POWER to activate the control panel.

 

 

 

 

Dryer is unplugged

• Make sure the dryer plug is pushed completely into

 

 

the outlet.

 

 

 

 

Fuse is blown/circuit breaker

• Check the building’s fuse/circuit breaker box and

 

is tripped

replace fuse or reset breaker. NOTE: Electric dryers

 

 

use two fuses or breakers.

 

 

 

 

Dryer was accidentally paused

• If the light on the START/PAUSE button is flashing,

 

when starting Delay Start

the dryer is paused. Press START/PAUSE to restart

 

 

the countdown.

 

 

 

No numbers displayed

Dryer is continuously

• This is normal. When the dryer senses a low level of

during cycle, only lights

monitoring the amount of

moisture in the load, the dryer will display the dry time

44

moisture in the clothes

remaining.

 

 

Page 44
Image 44
GE UPVH890 installation instructions Before you call for service…

UPVH890 specifications

The GE UPVH890 is a state-of-the-art ultrasound machine that redefines imaging capabilities in the medical field. It is designed for comprehensive diagnostic applications, emphasizing portability, versatility, and advanced imaging technologies. This device stands at the intersection of functionality and user-friendliness, making it a valuable asset in various healthcare settings, from hospitals to outpatient clinics.

One of the main features of the UPVH890 is its lightweight design. Weighing significantly less than traditional ultrasound machines, it offers unparalleled portability, allowing healthcare providers to transport it easily from room to room or even to remote locations. This is particularly advantageous in emergency situations where rapid ultrasound assessments are crucial.

The UPVH890 employs cutting-edge imaging technologies, including advanced three-dimensional and four-dimensional imaging capabilities. These features enable clinicians to visualize complex anatomical structures in real-time, enhancing diagnostic accuracy. The system is equipped with enhanced Doppler imaging, crucial for evaluating blood flow, and provides high-resolution images that aid in better assessment of conditions.

Additionally, the device incorporates artificial intelligence (AI) algorithms, which streamline the workflow and improve image interpretation. The built-in AI assists clinicians by providing automated measurements and suggesting the most likely diagnosis based on the obtained data, ultimately leading to quicker and more accurate patient care.

The UPVH890 also boasts an intuitive touchscreen interface that facilitates easy navigation through various settings and functions. This feature reduces the learning curve for new users and enhances efficiency for experienced operators. The customizable user interface allows healthcare providers to tailor the machine's settings according to their specific preferences and the needs of their patients.

In terms of connectivity, the UPVH890 supports wireless communication, enabling seamless integration with electronic medical record (EMR) systems. This capability ensures that patient information is readily available, promoting coordinated care and efficient follow-up processes.

Overall, the GE UPVH890 ultrasound machine stands out for its innovative features, intelligent technologies, and user-centric design that collectively enhance diagnostic efficiency and patient care. It represents a significant advancement in the field of medical imaging, catering to a wide range of clinical needs while ensuring ease of use and accessibility.